Your browser doesn't support javascript.
loading
Reliability of muscle stiffness measures in popliteus, medial and lateral gastrocnemius muscles by ultrasound shear wave elastography in participants with knee osteoarthritis accompanied by myofascial trigger points.
Shams, Mohsen; Karimi, Noureddin; Vahedi, Mohsen; Hakim, Peyman Kamali; Zeinalkhani, Fahimeh; Rahnama, Leila.
Afiliación
  • Shams M; Department of Physiotherapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran.
  • Karimi N; Department of Physiotherapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran. karimi@uswr.ac.ir.
  • Vahedi M; Department of Biostatistics and Epidemiology, Substance Abuse and Dependence Research Center, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran.
  • Hakim PK; Department of Radiology, Tehran University of Medical Sciences, Imam Khomeini Hospital, Tehran, Iran.
  • Zeinalkhani F; Department of Radiology, Tehran University of Medical Sciences, Imam Khomeini Hospital, Tehran, Iran.
  • Rahnama L; Rongxiang Xu School of Health and Human Services, California State University, Los Angeles, Los Angeles, CA, USA.
BMC Musculoskelet Disord ; 25(1): 221, 2024 Mar 19.
Article en En | MEDLINE | ID: mdl-38504204
ABSTRACT

BACKGROUND:

The objective of this investigation is to evaluate the consistency of intra-rater and inter-rater assessments utilizing ultrasound elastography to examine the muscle stiffness of the popliteus and gastrocnemius (medial and lateral heads) in patients with knee osteoarthritis accompanied by myofascial trigger points.

METHODS:

Thirty individuals with knee osteoarthritis accompanied by myofascial trigger points were assessed. Two examiners independently measured the muscle stiffness levels of the popliteus and gastrocnemius (medial and lateral heads) three times using ultrasound elastography in the first session. The second session was conducted one week later.

RESULTS:

In the initial test session, the mean shear modulus values for the popliteus and gastrocnemius (medial and lateral heads) muscles were measured as follows for tester 1 (12.75, 13.72, 14.13 kPa) and tester 2 (11.66, 12.81, 13.17 kPa). During the retest session, the previously measured variables by tester 1 and tester 2 yielded the following values (12.61, 13.43, 14.26 kPa) and (11.62, 12.87, 13.30 kPa) respectively." Good to excellent intra-rater reliability (ICC = 0.912-0.986) and inter-rater reliability (ICC = 0.766-0.956) were reported for the shear moduli of the popliteus, medial and lateral gastrocnemius muscles.

CONCLUSIONS:

The assessment of muscle stiffness in the popliteus and gastrocnemius (medial and lateral heads) using ultrasound elastography is a reliable method in patients with knee osteoarthritis accompanied by myofascial trigger points.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Osteoartritis de la Rodilla / Diagnóstico por Imagen de Elasticidad Límite: Humans Idioma: En Revista: BMC Musculoskelet Disord / BMC musculoskelet. disord. (Online) / BMC musculoskeletal disorders (Online) Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2024 Tipo del documento: Article País de afiliación: Irán

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Osteoartritis de la Rodilla / Diagnóstico por Imagen de Elasticidad Límite: Humans Idioma: En Revista: BMC Musculoskelet Disord / BMC musculoskelet. disord. (Online) / BMC musculoskeletal disorders (Online) Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2024 Tipo del documento: Article País de afiliación: Irán
...