Your browser doesn't support javascript.
loading
Distal femur morphology and the suitability of standard guides for knee arthroplasty in the Turkish population.
Incesoy, Mustafa Alper; Güngören, Nurdan; Aliyev, Orkhan; Elmali, Nurzat; Tuncay, Ibrahim; Yildiz, Fatih.
Afiliación
  • Incesoy MA; Department of Orthopaedics and Traumatology, Bezmialem Vakif University, Istanbul, Turkey.
  • Güngören N; Department of Orthopaedics and Traumatology, Universitätsklinikum Tübingen, Tübingen, Germany.
  • Aliyev O; Department of Orthopaedics and Traumatology, Rotkreuzklinik Wertheim, Wertheim, Germany.
  • Elmali N; Department of Orthopaedics and Traumatology, Bezmialem Vakif University, Istanbul, Turkey.
  • Tuncay I; Department of Orthopaedics and Traumatology, Bezmialem Vakif University, Istanbul, Turkey.
  • Yildiz F; Department of Orthopaedics and Traumatology, Bezmialem Vakif University, Istanbul, Turkey.
Acta Orthop Traumatol Turc ; 58(1): 39-44, 2024 01.
Article en En | MEDLINE | ID: mdl-38525509
ABSTRACT

OBJECTIVE:

The aim of this study was to evaluate the posterior condylar angle (PCA) and condylar twist angle (CTA) of the distal femur in the Turkish population and its concordance with the current standard prosthesis guides used in total knee arthroplasty (TKA).

METHODS:

Two hundred and forty knees of 120 Turkish subjects (60 male and 60 female) were included in this study. PCA, CTA, femoral mediolateral lengths (fML), medial femoral anteroposterior lengths (fMAP), lateral femoral anteroposterior lengths (fLAP), distances between the trochlear groove and fMAP (DBTG-fMAP), distances between the trochlear groove and fLAP (DBTG-fLAP), medial posterior condylar cartilage thickness (MPCCT) and lateral posterior condylar cartilage thicknesses (LPCCT) were measured on magnetic resonance imaging (MRI).

RESULTS:

The median CTA was 7° (range 0°-13.0°) and the median PCA was 4° (range 0°-11.0°) (P < .0001). The median fML was 79.5 mm (range 65.7-98.9). The median length of the fMAP was 58.2 mm (range 46.8-69.0) and the median length of fLAP was 58.2 mm (range 48.4-73.0). The DBTG-fMAP was 15.2 mm (range 5.2-23.2), and DBTG-fLAP length was 21.9mm (range 16.4-29.4). The median MPCCT and LPCCT were 2.4 mm (range 1.6-3.6) and 2.3 mm (range 1.2-2.8), respectively. The intraclass correlation coefficient for quantifying interobserver and intraobserver reliability showed excellent agreement regarding the PCA and CTA.

CONCLUSION:

This study has shown us that PCA and CTA may be higher in the Turkish population. Although it is not known whether these results have any clinical utility, it may be useful for surgeons to keep this in mind to prevent femoral component malposition. LEVEL OF EVIDENCE Level IV, Diagnostic Study.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Rodilla / Osteoartritis de la Rodilla Límite: Female / Humans / Male Idioma: En Revista: Acta Orthop Traumatol Turc Asunto de la revista: ORTOPEDIA / TRAUMATOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Turquía

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Rodilla / Osteoartritis de la Rodilla Límite: Female / Humans / Male Idioma: En Revista: Acta Orthop Traumatol Turc Asunto de la revista: ORTOPEDIA / TRAUMATOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Turquía
...