Your browser doesn't support javascript.
loading
Paper spray mass spectrometry combined with machine learning as a rapid diagnostic for chronic kidney disease.
Pereira, Igor; Sboto, Jindar N S; Robinson, Jason L; Gill, Chris G.
Afiliación
  • Pereira I; Applied Environmental Research Laboratories (AERL), Chemistry Department, Vancouver Island University, 900 Fifth Street, Nanaimo, BC, V9R 5S5, Canada. chris.gill@viu.ca.
  • Sboto JNS; Applied Environmental Research Laboratories (AERL), Chemistry Department, Vancouver Island University, 900 Fifth Street, Nanaimo, BC, V9R 5S5, Canada. chris.gill@viu.ca.
  • Robinson JL; Health PEI, Charlottetown, PEI, C1A 7N8, Canada.
  • Gill CG; Applied Environmental Research Laboratories (AERL), Chemistry Department, Vancouver Island University, 900 Fifth Street, Nanaimo, BC, V9R 5S5, Canada. chris.gill@viu.ca.
Analyst ; 149(9): 2600-2608, 2024 Apr 29.
Article en En | MEDLINE | ID: mdl-38529879
ABSTRACT
A new analytical method for chronic kidney disease (CKD) detection utilizing paper spray mass spectrometry (PS-MS) combined with machine learning is presented. The analytical protocol is rapid and simple, based on metabolic profile alterations in urine. Anonymized raw urine samples were deposited (10 µL each) onto pointed PS-MS sample strips. Without waiting for the sample to dry, 75 µL of acetonitrile and high voltage were applied to the strips, using high resolution mass spectrometry measurement (15 s per sample) with polarity switching to detect a wide range of metabolites. Random forest machine learning was used to classify the resulting data. The diagnostic performance for the potential diagnosis of CKD was evaluated for accuracy, sensitivity, and specificity, achieving results >96% for the training data and >91% for validation and test data sets. Metabolites selected by the classification model as up- or down-regulated in healthy or CKD samples were tentatively identified and in agreement with previously reported literature. The potential utilization of this approach to discriminate albuminuria categories (normo, micro, and macroalbuminuria) was also demonstrated. This study indicates that PS-MS combined with machine learning has the potential to be used as a rapid and simple diagnostic tool for CKD.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría de Masas / Insuficiencia Renal Crónica / Aprendizaje Automático Límite: Humans Idioma: En Revista: Analyst Año: 2024 Tipo del documento: Article País de afiliación: Canadá

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría de Masas / Insuficiencia Renal Crónica / Aprendizaje Automático Límite: Humans Idioma: En Revista: Analyst Año: 2024 Tipo del documento: Article País de afiliación: Canadá
...