Your browser doesn't support javascript.
loading
Functional Green-Emitting Mn2+-doped Zinc Germanate Persistent Luminescent Nanoparticles for Dual-Mode Immunochromatographic Detection.
Gao, Yan; Shi, Junpeng; Wu, Chen; Cao, Longlong; Liu, Lin; Wang, Jinyuan; Luo, Xiaofang; Zhang, Xiao; Zhang, Yun.
Afiliación
  • Gao Y; State Key Laboratory of Structural Chemistry, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou 350002, China.
  • Shi J; Xiamen Key Laboratory of Rare Earth Photoelectric Functional Materials, Xiamen Institute of Rare Earth Materials, Haixi Institute, Chinese Academy of Sciences, Xiamen 361021, China.
  • Wu C; School of Rare Earths University of Science and Technology of China, Hefei 230026, China.
  • Cao L; Ganjiang Innovation Academy, Chinese Academy of Science, Ganzhou 341000, China.
  • Liu L; State Key Laboratory of Structural Chemistry, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou 350002, China.
  • Wang J; Xiamen Key Laboratory of Rare Earth Photoelectric Functional Materials, Xiamen Institute of Rare Earth Materials, Haixi Institute, Chinese Academy of Sciences, Xiamen 361021, China.
  • Luo X; School of Rare Earths University of Science and Technology of China, Hefei 230026, China.
  • Zhang X; Ganjiang Innovation Academy, Chinese Academy of Science, Ganzhou 341000, China.
  • Zhang Y; State Key Laboratory of Structural Chemistry, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou 350002, China.
Anal Chem ; 96(14): 5694-5701, 2024 04 09.
Article en En | MEDLINE | ID: mdl-38538547
ABSTRACT
Immunochromatography is a commonly used immediate detection technique, using signal labels to generate detection signals for rapid medical diagnosis. However, its detection sensitivity is affected by background fluorescence caused by the excitation light source. We have developed an immunochromatographic test strip using Zn2GeO4Mn2+ (ZGM) persistent luminescent nanoparticles (PLNPs) for immediate fluorescence detection and highly sensitive persistent luminescence (PersL) detection without background fluorescence interference. ZGM emits a strong green light when exposed to ultraviolet (UV) excitation, and its green PersL can persist for over 30 min after the excitation light is turned off. We modified the surface of ZGM with heparin-binding protein (HBP) antibodies to create immunochromatographic test strips for the detection of HBP as the target analyte. Under UV excitation, the chromatography test paper can be visually observed at concentrations as low as 25 ng/mL. After the excitation light source is switched off, PersL can achieve a detection limit of 4.7 ng/mL without background interference. This dual-mode immunochromatographic detection, based on ZGM, shows great potential for in vitro diagnostic applications.