Your browser doesn't support javascript.
loading
A novel tryptanthrin-based "on-off-on" probe for sequential sensing Cu2+/S2- in water samples.
Wang, Cuiling; Zhou, Ying; Liu, RongRong; Shang, Dongyuan; Jin, Kangrui; Wang, Jinrui; Liu, Jianli; Hou, Bao-Long.
Afiliación
  • Wang C; Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, College of Life Science, Northwest University, Xi'an, 710069, China.
  • Zhou Y; Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, College of Life Science, Northwest University, Xi'an, 710069, China.
  • Liu R; Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, College of Life Science, Northwest University, Xi'an, 710069, China.
  • Shang D; Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, College of Life Science, Northwest University, Xi'an, 710069, China.
  • Jin K; Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, College of Life Science, Northwest University, Xi'an, 710069, China.
  • Wang J; Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, College of Life Science, Northwest University, Xi'an, 710069, China.
  • Liu J; Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, College of Life Science, Northwest University, Xi'an, 710069, China.
  • Hou BL; Xi'an Peihua University, Xi'an, 710125, China.
Anal Sci ; 40(7): 1279-1287, 2024 Jul.
Article en En | MEDLINE | ID: mdl-38573453
ABSTRACT
Copper ions (Cu2+) and sulfide (S2-) play essential roles in many physiologies and pathologic processes. Herein, a new "on-off-on" tryptanthrin-based probe TR-1 (TR-1) has been designed and synthesized in a facile and economical way. TR-1 exhibited highly selective and sensitive response to Cu2+ without any interference over 14 competitive metal ions and the detection limit downs to 24 nM, which is far below the Chinese standard of fishery water quality (157 nM). The 'in situ' prepared complex TR-1 + Cu2+ could also be applied to detect S2- with the detection limit of 62 nM. Further, TR-1 was potentially applied for the analysis of copper ions in water samples.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Anal Sci Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Anal Sci Año: 2024 Tipo del documento: Article País de afiliación: China
...