Can Plasma Volume Determination in Cirrhosis Be Replaced by an Algorithm Using Body Weight and Hematocrit?
Nørskov, Martine Prütz; Mønsted, Thormod; Kimer, Nina; Damgaard, Morten; Møller, Søren.
Afiliación
  • Nørskov MP; Center of Functional and Diagnostic Imaging and Research, Department of Clinical Physiology and Nuclear Medicine 260, Copenhagen University Hospital, 2650 Hvidovre, Denmark.
  • Mønsted T; Center of Functional and Diagnostic Imaging and Research, Department of Clinical Physiology and Nuclear Medicine 260, Copenhagen University Hospital, 2650 Hvidovre, Denmark.
  • Kimer N; Gastro Unit, Medical Division, Copenhagen University Hospital, 2650 Hvidovre, Denmark.
  • Damgaard M; Center of Functional and Diagnostic Imaging and Research, Department of Clinical Physiology and Nuclear Medicine 260, Copenhagen University Hospital, 2650 Hvidovre, Denmark.
  • Møller S; Department of Clinical Medicine, Faculty of Health and Medical Sciences, Copenhagen University, 2200 Copenhagen, Denmark.
Diagnostics (Basel) ; 14(8)2024 Apr 17.
Article en En | MEDLINE | ID: mdl-38667480
ABSTRACT

BACKGROUND:

Patients with cirrhosis often develop hyperdynamic circulation with increased cardiac output, heart rate, and redistribution of the circulating volume with expanded plasma volume (PV). PV determination is part of the evaluation of patients with cirrhosis, but gold-standard methods are invasive, expensive, and time-consuming. Therefore, other estimations of PV would be preferable, and the aim of this study was therefore to study if PV, as assessed by a simplified algorithm based on hematocrit and weight, can replace the gold-standard method.

METHODS:

We included 328 patients with cirrhosis who had their PV assessed by the indicator dilution technique as the gold-standard method (PVI-125). Actual PV was estimated as PVa = (1 - hematocrit)·(a + (b·body weight)). Ideal PV was estimated as PVi = c · body weight, where a, b, and c are constants.

RESULTS:

PVI-125, PVa, and PVi were 3.99 ± 1.01, 3.09 ± 0.54, and 3.01 ± 0.65 (Mean ± SD), respectively. Although PVI-125 correlated significantly with PVa (r = 0.72, p < 0.001), a Bland-Altman plot revealed wide limits of confidence.

CONCLUSIONS:

The use of simplified algorithms does not sufficiently estimate PV and cannot replace the indicator dilution technique.