Your browser doesn't support javascript.
loading
Development of benzimidazole derivatives as efficient matrices for the analysis of acidic small-molecule compounds using matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry in negative ion mode.
Cen, Xianyi; Fang, Yuhao; Chen, Zilong; Zhu, Xinhai.
Afiliación
  • Cen X; School of Chemistry, Sun Yat-sen University, Guangzhou, China.
  • Fang Y; School of Chemistry, Sun Yat-sen University, Guangzhou, China.
  • Chen Z; Instrumental Analysis & Research Center, Sun Yat-sen University, Guangzhou, China.
  • Zhu X; Instrumental Analysis & Research Center, Sun Yat-sen University, Guangzhou, China.
Rapid Commun Mass Spectrom ; 38(13): e9751, 2024 Jul 15.
Article en En | MEDLINE | ID: mdl-38680091
ABSTRACT
RATIONALE With the development of matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry (MS) in spatial localisation omics research on small molecules, the detection sensitivity of the matrix must increase. However, the types of matrices suitable for detecting acidic small molecules in (-) MALDI-MS mode are very limited and are either not sensitive enough or difficult to obtain.

METHODS:

More than 10 commercially available benzimidazole and benzothiazole derivatives were selected as MALDI matrices in negative ion mode. MALDI-MS analysis was performed on 38 acidic small molecules and mouse serum, and the matrix effects were compared with those of the common commercial matrices 9-aminoacridine (9AA), 1,5-naphthalenediamine (DAN) and 3-aminoquinoline (3AQ). Moreover, the proton affinity (PA) of the selected potential matrix was calculated, and the relationships among the compound structure, PA value and matrix effect were discussed.

RESULTS:

In (-) MALDI-MS mode, a higher PA value generally indicates a better matrix effect. Amino-substituted 2-phenyl-1H-benzo[d]imidazole derivatives had well-defined matrix effects on all analytes and were generally superior to the commonly used matrices 9AA, DAN and 3AQ. Among them, 2-(4-(dimethylamino-phenyl)-1H-benzo[d]imidazole-5-amine (E-4) has the best sensitivity and versatility for detecting different analytes and has the best ability to detect fatty acids in mouse serum; moreover, the limit of detection (LOD) of some analytes can reach as low as ng/L.

CONCLUSIONS:

Compared to 9AA, DAN and 3AQ, matrix E-4 is more effective at detecting low-molecular-weight acidic compounds in (-) MALDI-MS mode, with higher sensitivity and better versatility. In addition, there is a clear correlation between compound structure, PA and matrix effects, which provides a basis for designing more efficient matrices.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Bencimidazoles / Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción Límite: Animals Idioma: En Revista: Rapid Commun Mass Spectrom / Rapid commun. mass spectrom / Rapid communications in mass spectrometry Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Bencimidazoles / Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción Límite: Animals Idioma: En Revista: Rapid Commun Mass Spectrom / Rapid commun. mass spectrom / Rapid communications in mass spectrometry Año: 2024 Tipo del documento: Article País de afiliación: China
...