The Application of a Synthetic Biodegradable Temporizing Matrix in Extensive Burn Injury: A Unicenter Experience of 175 Cases.
Tapking, Christian; Panayi, Adriana C; Hundeshagen, Gabriel; Thomas, Benjamin F; Gazyakan, Emre; Bliesener, Bjoern; Bigdeli, Amir K; Kneser, Ulrich; Vollbach, Felix H.
Afiliación
  • Tapking C; Department of Hand, Plastic and Reconstructive Surgery, Microsurgery, Burn Center, BG Unfallklinik Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, 67071 Ludwigshafen, Germany.
  • Panayi AC; Department of Hand, Plastic and Reconstructive Surgery, Microsurgery, Burn Center, BG Unfallklinik Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, 67071 Ludwigshafen, Germany.
  • Hundeshagen G; Department of Hand, Plastic and Reconstructive Surgery, Microsurgery, Burn Center, BG Unfallklinik Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, 67071 Ludwigshafen, Germany.
  • Thomas BF; Department of Hand, Plastic and Reconstructive Surgery, Microsurgery, Burn Center, BG Unfallklinik Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, 67071 Ludwigshafen, Germany.
  • Gazyakan E; Department of Hand, Plastic and Reconstructive Surgery, Microsurgery, Burn Center, BG Unfallklinik Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, 67071 Ludwigshafen, Germany.
  • Bliesener B; Department of Hand, Plastic and Reconstructive Surgery, Microsurgery, Burn Center, BG Unfallklinik Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, 67071 Ludwigshafen, Germany.
  • Bigdeli AK; Department of Hand, Plastic and Reconstructive Surgery, Microsurgery, Burn Center, BG Unfallklinik Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, 67071 Ludwigshafen, Germany.
  • Kneser U; Department of Hand, Plastic and Reconstructive Surgery, Microsurgery, Burn Center, BG Unfallklinik Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, 67071 Ludwigshafen, Germany.
  • Vollbach FH; Department of Hand, Plastic and Reconstructive Surgery, Microsurgery, Burn Center, BG Unfallklinik Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, 67071 Ludwigshafen, Germany.
J Clin Med ; 13(9)2024 May 01.
Article en En | MEDLINE | ID: mdl-38731190
ABSTRACT

Objectives:

Addressing extensive and deep burn wounds poses considerable challenges for both patients and surgeons. The NovoSorb® Biodegradable Temporizing Matrix (BTM) emerged as a novel dermal substitute and has been subjected to evaluation in large burn wound cases, with a specific focus on identifying risk factors associated with suboptimal take rates.

Methods:

All patients with burn wounds greater than 10% body surface that underwent BTM treatment between March 2020 and November 2023 were eligible for inclusion. Univariate analyses and linear regression models were employed to discern risk factors and predictors influencing the take rates of both the BTM and split-thickness skin grafts (STSGs).

Results:

A total of 175 patients (mean age 56.2 ± 19.8 years, 70.3% male) were evaluated. The mean take rates of the BTM and STSGs were 82.0 ± 24.7% and 87.3 ± 19.0%, respectively. There were significant negative correlations between BTM take and the number of surgeries before BTM application (r = -0.19, p = 0.01), %TBSA and STSG take (r = -0.36, p = <0.001) and significant positive correlations between BTM and STSG take (r = 0.41, p ≤ 0.001) in addition to NPWT and STSG take (r = 0.21, p = 0.01). Multivariate regression analyses showed that a larger number of surgeries prior to BTM application (OR -3.41, 95% CI -6.82, -0.03, p = 0.04) was associated with poorer BTM take. Allograft treatment before BTM application (OR -14.7, 95% CI -23.0, -6.43,p = 0.01) and failed treatment with STSG before BTM application (OR -20.8, 95% CI -36.3, -5.23, p ≤ 0.01) were associated with poorer STSG take, whereas higher BTM take rates were associated with overall higher STSG take (OR -0.15, 95% 0.05, 0.26, p = 0.01). The Meek technique was used in 24 patients and showed similar take rates (BTM 76.3 ± 28.0%, p = 0.22; STSG 80.7 ± 21.1, p = 0.07).

Conclusions:

This study summarizes our findings on the application of a BTM in the context of large burn wounds. The results demonstrate that successful treatment can be achieved even in patients with extensive burns, resulting in satisfying take rates for both the BTM and STSG. The data underscore the importance of promptly applying a BTM to debrided wounds and indicate good results when using Meek.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Clin Med Año: 2024 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Clin Med Año: 2024 Tipo del documento: Article País de afiliación: Alemania
...