Your browser doesn't support javascript.
loading
Revolutionizing Glucose Monitoring: Enzyme-Free 2D-MoS2 Nanostructures for Ultra-Sensitive Glucose Sensors with Real-Time Health-Monitoring Capabilities.
Bano, Mustri; Naikoo, Gowhar A; BaOmar, Fatima; Rather, Jahangir Ahmad; Hassan, Israr U; Sheikh, Rayees Ahmad; Kannan, Palanisamy; Tambuwala, Murtaza M.
Afiliación
  • Bano M; Department of Mathematics and Sciences, College of Arts and Applied Sciences, Dhofar University, Salalah, PC 211, Oman.
  • Naikoo GA; Department of Mathematics and Sciences, College of Arts and Applied Sciences, Dhofar University, Salalah, PC 211, Oman.
  • BaOmar F; Department of Mathematics and Sciences, College of Arts and Applied Sciences, Dhofar University, Salalah, PC 211, Oman.
  • Rather JA; Department of Chemistry, Sri Pratap College Srinagr-190001 Kashmir, India.
  • Hassan IU; Department of Mathematics and Sciences, College of Arts and Applied Sciences, Dhofar University, Salalah, PC 211, Oman.
  • Sheikh RA; Department of Chemistry, AAAM Degree College Bemina Srinagar - 190018 Kashmir, India.
  • Kannan P; College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, PR China.
  • Tambuwala MM; College of Pharmacy, Ras Al Khaimah Medical and Health Sciences University, Ras Al Khaimah, United Arab Emirates.
ACS Omega ; 9(18): 20021-20029, 2024 May 07.
Article en En | MEDLINE | ID: mdl-38737026
ABSTRACT
The growing requirement for real-time monitoring of health factors such as heart rate, temperature, and blood glucose levels has resulted in an increase in demand for electrochemical sensors. This study focuses on enzyme-free glucose sensors based on 2D-MoS2 nanostructures explored by simple hydrothermal route. The 2D-MoS2 nanostructures were characterized by powder X-ray diffraction, energy-dispersive X-ray spectroscopy, scanning electron microscopy, transmission electron microscopy, Raman spectroscopy, and XPS techniques and were immobilized at GCE to obtain MoS2-GCE interface. The fabricated interface was characterized by electrochemical impedance spectroscopy which shows less charge transfer resistance and demonstrated superior electrocatalytic properties of the modified surface. The sensing interface was applied for the detection of glucose using amperometry. The MoS2-GCE-sensing interface responded effectively as a nonenzymatic glucose sensor (NEGS) over a linearity range of 0.01-0.20 µM with a very low detection limit of 22.08 ng mL-1. This study demonstrates an easy method for developing a MoS2-GCE interface, providing a potential option for the construction of flexible and disposable nonenzymatic glucose sensors (NEGS). Moreover, the fabricated MoS2-GCE electrode precisely detected glucose molecules in real blood serum and urine samples of diabetic and nondiabetic persons. These findings suggest that 2D-MoS2 nanostructured materials show considerable promise as a possible option for hyperglycemia detection and therapy. Furthermore, the development of NEGS might create new prospects in the glucometer industry.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: ACS Omega Año: 2024 Tipo del documento: Article País de afiliación: Omán

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: ACS Omega Año: 2024 Tipo del documento: Article País de afiliación: Omán
...