Your browser doesn't support javascript.
loading
Determination of fifteen illegal colorants in traditional Chinese medicines by two hydrophobic DES-based microextraction methods coupled with an HPLC-DAD.
Peng, Jiaqing; Hassan, Farhia Abdulnur; Wu, Jianhong; Xiong, Chaomei.
Afiliación
  • Peng J; Department of Pharmaceutical Analysis, School of Pharmacy, Tongji Medical College, Huazhong University of Science and Technology, China; Ezhou Center for Food and Drug Control, China.
  • Hassan FA; Department of Pharmaceutical Analysis, School of Pharmacy, Tongji Medical College, Huazhong University of Science and Technology, China.
  • Wu J; NMPA Key Laboratory for Quality Research and Control of Drug Products, Wuhan Institute for Drug and Medical Device Control, Wuhan, 430075, China.
  • Xiong C; Department of Pharmaceutical Analysis, School of Pharmacy, Tongji Medical College, Huazhong University of Science and Technology, China; NMPA Key Laboratory for Quality Research and Control of Drug Products, Wuhan Institute for Drug and Medical Device Control, Wuhan, 430075, China. Electronic addres
Talanta ; 277: 126236, 2024 Sep 01.
Article en En | MEDLINE | ID: mdl-38795590
ABSTRACT
The dyeing and adulteration of traditional Chinese medicines (TCMs) are continuously updated. Valuable analytical methods for the daily inspection of illegal colorant additives in TCMs and the preparations are in demand. Two deep eutectic solvent (DES)-based vortex-assisted liquid-liquid microextraction (VA-LLME) and ultrasonic-assisted solid-liquid microextraction (UA-SLME) were developed for the sample pretreatment of ten water-soluble colorants and five water-insoluble colorants, respectively, followed by an HPLC-DAD detection. Fifteen colorants were analyzed at four detection wavelengths within 40 min of gradient elution. The optimal DES of VA-LLME and UA-SLME were screened from 23 homemade DESs. The factors affecting the extraction efficiency of VA-LLME and UA-SLME were optimized systematically. Under the optimal conditions, ten water-soluble colorants analyzed by DES-based VA-LLME-HPLC-DAD showed good linearity (R ≥ 0.9995) within the optimal linear range. The LODs and LOQs were 0.2-1.0 µg g-1 and 0. 5-5.0 µg g-1, respectively. The recoveries of spiked samples were 80.2%-104.7 %, with RSDs ≤ 4.39 %. Five water-insoluble colorants of Sudan I‒IV and Sudan 7B analyzed by DES-based UA-SLME-HPLC-DAD showed good linearity (R ≥ 0.9995) within the optimal linear range. The LODs and LOQs were 0.8-8.0 µg g-1 and 4.0-40.0 µg g-1, respectively. The recoveries of spiked samples were 94.2%-103.1 %, with RSDs ≤ 4.81 %. The proposed DES-based VA-LLME-HPLC-DAD was successfully applied to analyze six water-soluble yellow colorants in Cuscutae Semen, salted Cuscutae Semen, and four water-soluble red colorants in Schisandrae Chinensis Fructus. The proposed DES-based UA-SLME-HPLC-DAD was successfully applied to analyze five water-insoluble red colorants in Dieda pills. The study provides analytical method options for routine tests of water-soluble, water-insoluble, or both water-soluble/-insoluble illegal colorant additives in herbal medical materials and preparations by the relevant proposed DES-based sample pretreatment method or a combination of the two proposed DES-based methods.