Your browser doesn't support javascript.
loading
Design and development of the DE-SPECT system: a clinical SPECT system for broadband multi-isotope imaging of peripheral vascular disease.
Zannoni, E M; Sankar, P; Jin, Y; Liu, C; Sinusas, A J; Metzler, S D; Meng, L J.
Afiliación
  • Zannoni EM; Department of Nuclear, Plasma, and Radiological Engineering, University of Illinois at Urbana Champaign, Urbana, IL, United States of America.
  • Sankar P; Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America.
  • Jin Y; Department of Nuclear, Plasma, and Radiological Engineering, University of Illinois at Urbana Champaign, Urbana, IL, United States of America.
  • Liu C; Department of Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, CT, United States of America.
  • Sinusas AJ; Department of Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, CT, United States of America.
  • Metzler SD; Department of Medicine, Yale University School of Medicine, New Haven, CT, United States of America.
  • Meng LJ; Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America.
Phys Med Biol ; 69(12)2024 Jun 11.
Article en En | MEDLINE | ID: mdl-38815617
ABSTRACT
Objective. Peripheral Vascular Disease (PVD) affects more than 230 million people worldwide and is one of the leading causes of disability among people over age 60. Nowadays, PVD remains largely underdiagnosed and undertreated, and requires the development of tailored diagnostic approaches. We present the full design of the Dynamic Extremity SPECT (DE-SPECT) system, the first organ-dedicated SPECT system for lower extremity imaging, based on 1 cm thick Cadmium Zinc Telluride (CZT) spectrometers and a dynamic dual field-of-view (FOV) synthetic compound-eye (SCE) collimator.Approach. The proposed DE-SPECT detection system consists of 48 1 cm thick 3D-position-sensitive CZT spectrometers arranged in a partial ring of 59 cm in diameter in a checkerboard pattern. The detection system is coupled with a compact dynamic SCE collimator that allows the user to select between two different FOVs at any time during an imaging study a wide-FOV (28 cm diameter) configuration for dual-leg or scout imaging or a high-resolution and high-sensitivity (HR-HS) FOV (16 cm diameter) for single-leg or focused imaging.Main results.The preliminary experimental data show that the CZT spectrometer achieves a 3D intrinsic spatial resolution of <0.75 mm FWHM and an excellent energy resolution over a broad energy range (2.6 keV FWHM at 218, 3.3 keV at 440 keV). From simulations, the wide-FOV configuration offers a 0.034% averaged sensitivity at 140 keV and <8 mm spatial resolution, whereas the HR-HS configuration presents a peak central sensitivity of 0.07% at 140 keV and a ∼5 mm spatial resolution. The dynamic SCE collimator enables the capability to perform joint reconstructions that would ensure an overall improvement in imaging performance.Significance. The DE-SPECT system is a stationary and high-performance SPECT system that offers an excellent spectroscopic performance with a unique computer-controlled dual-FOV imaging capability, and a relatively high sensitivity for multi-tracer and multi-functional SPECT imaging of the extremities.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tomografía Computarizada de Emisión de Fotón Único / Enfermedades Vasculares Periféricas / Diseño de Equipo Límite: Humans Idioma: En Revista: Phys Med Biol Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tomografía Computarizada de Emisión de Fotón Único / Enfermedades Vasculares Periféricas / Diseño de Equipo Límite: Humans Idioma: En Revista: Phys Med Biol Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos
...