Your browser doesn't support javascript.
loading
A comparative study of 3D measuring methods for monitoring breast volume changes.
Dijkman, Benthe A M; Liberton, Niels P T J; Te Slaa, Sjoerd; Smit, Jan Maerten; Wiepjes, Chantal M; Dreijerink, Koen M A; den Heijer, Martin; Verdaasdonk, Rudolf M; de Blok, Christel J M.
Afiliación
  • Dijkman BAM; Center of Expertise on Gender Dysphoria, Amsterdam UMC, VU University, Amsterdam, the Netherlands.
  • Liberton NPTJ; Department of Endocrinology and Metabolism, Amsterdam UMC, VU University, Amsterdam, the Netherlands.
  • Te Slaa S; Department of Medical Technology, 3D Innovation Lab, Amsterdam UMC, VU University, Amsterdam, the Netherlands.
  • Smit JM; Department of Medical Technology, 3D Innovation Lab, Amsterdam UMC, VU University, Amsterdam, the Netherlands.
  • Wiepjes CM; Center of Expertise on Gender Dysphoria, Amsterdam UMC, VU University, Amsterdam, the Netherlands.
  • Dreijerink KMA; Department of Plastic, Reconstructive and Hand Surgery, Amsterdam Movement Sciences, Amsterdam UMC, VU University, Amsterdam, the Netherlands.
  • den Heijer M; Center of Expertise on Gender Dysphoria, Amsterdam UMC, VU University, Amsterdam, the Netherlands.
  • Verdaasdonk RM; Department of Endocrinology and Metabolism, Amsterdam UMC, VU University, Amsterdam, the Netherlands.
  • de Blok CJM; Center of Expertise on Gender Dysphoria, Amsterdam UMC, VU University, Amsterdam, the Netherlands.
PLoS One ; 19(6): e0305059, 2024.
Article en En | MEDLINE | ID: mdl-38843166
ABSTRACT
Three-dimensional (3D) imaging techniques are promising new tools for measuring breast volume, for example in gender-affirming therapy. Transgender individuals can be treated with gender-affirming hormone therapy (GAHT). A robust method for monitoring breast volume changes is critical to be able to study the effects of feminizing GAHT. The primary aim of this study was to compare the accuracy of three 3D devices (Vectra XT, Artec LEO and iPhone XR) for measuring modest breast volume differences using a mannequin. The secondary aim of this study was to evaluate these methods in several performance domains. We used reference prostheses of increasing volumes and compared the volumes using GOM-inspect software. For Vectra XT 3D images, manufacturer-provided software was used to calculate volumes as well. The scanning methods were ranked based on their performance in a total of five categories volume estimations, costs, user-friendliness, test subject-friendliness and technical aspects. The 3D models analyzed with GOM-inspect showed relative mean estimate differences from the actual volumes of 9.1% for the Vectra XT, 7.3% for the Artec LEO and 14% for the iPhone XR. For the Vectra XT models analyzed with the built-in software this was 6.2%. Root mean squared errors (RMSE) calculated based on the GOM-inspect volume analyses showed mean RMSEs of 2.27, 2.54 and 8.93 for the Vectra XT, Artec LEO and iPhone XR, respectively. The Vectra software had a mean RMSE of 3.00. In the combined performance ranking, the Vectra XT had the most favorable ranking, followed by the Artec LEO and the iPhone XR. The Vectra XT and Artec LEO are the preferred scanners to monitor breast development due to the combination of higher accuracy and overall performance. The current study shows that 3D techniques can be used to adequately measure modest breast volume differences and therefore will be useful to study for example breast changes in transgender individuals using feminizing GAHT. These observations may also be relevant in other fields of 3D imaging research.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Mama / Imagenología Tridimensional Límite: Female / Humans / Male Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2024 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Mama / Imagenología Tridimensional Límite: Female / Humans / Male Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2024 Tipo del documento: Article País de afiliación: Países Bajos
...