Your browser doesn't support javascript.
loading
Bioprocess monitoring applications of an innovative ATR-FTIR spectroscopy platform.
Christie, Loren; Rutherford, Samantha; Palmer, David S; Baker, Matthew J; Butler, Holly J.
Afiliación
  • Christie L; Dxcover Ltd., Glasgow, United Kingdom.
  • Rutherford S; Pure and Applied Chemistry, University of Strathclyde, Glasgow, United Kingdom.
  • Palmer DS; Pure and Applied Chemistry, University of Strathclyde, Glasgow, United Kingdom.
  • Baker MJ; Dxcover Ltd., Glasgow, United Kingdom.
  • Butler HJ; Pure and Applied Chemistry, University of Strathclyde, Glasgow, United Kingdom.
Front Bioeng Biotechnol ; 12: 1349473, 2024.
Article en En | MEDLINE | ID: mdl-38863496
ABSTRACT
Pharmaceutical manufacturing is reliant upon bioprocessing approaches to generate the range of therapeutic products that are available today. The high cost of production, susceptibility to process failure, and requirement to achieve consistent, high-quality product means that process monitoring is paramount during manufacturing. Process analytic technologies (PAT) are key to ensuring high quality product is produced at all stages of development. Spectroscopy-based technologies are well suited as PAT approaches as they are non-destructive and require minimum sample preparation. This study explored the use of a novel attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy platform, which utilises disposable internal reflection elements (IREs), as a method of upstream bioprocess monitoring. The platform was used to characterise organism health and to quantify cellular metabolites in growth media using quantification models to predict glucose and lactic acid levels both singularly and combined. Separation of the healthy and nutrient deficient cells within PC space was clearly apparent, indicating this technique could be used to characterise these classes. For the metabolite quantification, the binary models yielded R 2 values of 0.969 for glucose, 0.976 for lactic acid. When quantifying the metabolites in tandem using a multi-output partial least squares model, the corresponding R 2 value was 0.980. This initial study highlights the suitability of the platform for bioprocess monitoring and paves the way for future in-line developments.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Front Bioeng Biotechnol Año: 2024 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Front Bioeng Biotechnol Año: 2024 Tipo del documento: Article País de afiliación: Reino Unido
...