Assessing the Progress of the Performance of Continuous Monitoring Solutions under a Single-Blind Controlled Testing Protocol.
Ilonze, Chiemezie; Emerson, Ethan; Duggan, Aidan; Zimmerle, Daniel.
Afiliación
  • Ilonze C; Department of Mechanical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States.
  • Emerson E; Energy Institute, Colorado State University, Fort Collins, Colorado 80524, United States.
  • Duggan A; Energy Institute, Colorado State University, Fort Collins, Colorado 80524, United States.
  • Zimmerle D; Energy Institute, Colorado State University, Fort Collins, Colorado 80524, United States.
Environ Sci Technol ; 58(25): 10941-10955, 2024 Jun 25.
Article en En | MEDLINE | ID: mdl-38865299
ABSTRACT
The recent regulatory spotlight on continuous monitoring (CM) solutions and the rapid development of CM solutions have demanded the characterization of solution performance through regular, rigorous testing using consensus test protocols. This study is the second known implementation of such a protocol involving single-blind controlled testing of 9 CM solutions. Controlled releases of rates (6-7100 g) CH4/h over durations (0.4-10.2 h) under a wind speed range of (0.7-9.9 m/s) were conducted for 11 weeks. Results showed that 4 solutions achieved method detection limits (DL90s) within the tested emission rate range, with all 4 solutions having both the lowest DL90s (3.9 [3.0, 5.5] kg CH4/h to 6.2 [3.7, 16.7] kg CH4/h) and false positive rates (6.9-13.2%), indicating efforts at balancing low sensitivity with a low false positive rate. These results are likely best-case scenario estimates since the test center represents a near-ideal upstream field natural gas operation condition. Quantification results showed wide individual estimate uncertainties, with emissions underestimation and overestimation by factors up to >14 and 42, respectively. Three solutions had >80% of their estimates within a quantification factor of 3 for controlled releases in the ranges of [0.1-1] kg CH4/h and > 1 kg CH4/h. Relative to the study by Bell et al., current solutions performance, as a group, generally improved, primarily due to solutions from the study by Bell et al. that were retested. This result highlights the importance of regular quality testing to the advancement of CM solutions for effective emissions mitigation.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Monitoreo del Ambiente Idioma: En Revista: Environ Sci Technol Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Monitoreo del Ambiente Idioma: En Revista: Environ Sci Technol Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos
...