Your browser doesn't support javascript.
loading
Comparison of staining quality between rapid and routine hematoxylin and eosin staining of frozen breast tissue sections: an observational study.
Ma, Zhen Yi; Zhang, Xiao Fang; Hu, Yan Ze; Zhu, Min Da; Jin, Jia; Qian, Ping.
Afiliación
  • Ma ZY; Department of Pathology and Clinical Laboratory, Jiaxing Hospital of Traditional Chinese Medicine, Jiaxing University, Jiaxing, China.
  • Zhang XF; Department of Pathology and Clinical Laboratory, Jiaxing Hospital of Traditional Chinese Medicine, Jiaxing University, Jiaxing, China.
  • Hu YZ; Department of Pathology and Clinical Laboratory, Jiaxing Hospital of Traditional Chinese Medicine, Jiaxing University, Jiaxing, China.
  • Zhu MD; Department of Pathology and Clinical Laboratory, Jiaxing Hospital of Traditional Chinese Medicine, Jiaxing University, Jiaxing, China.
  • Jin J; College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China.
  • Qian P; Department of Pathology and Clinical Laboratory, Jiaxing Hospital of Traditional Chinese Medicine, Jiaxing University, Jiaxing, China.
J Int Med Res ; 52(6): 3000605241259682, 2024 Jun.
Article en En | MEDLINE | ID: mdl-38886869
ABSTRACT

OBJECTIVE:

To compare the staining quality between rapid hematoxylin and eosin (H&E) staining and routine H&E staining of frozen breast tissue sections.

METHODS:

In this cross-sectional observational study, 120 frozen breast tissue sections were randomly assigned to rapid or routine H&E staining (n = 60 per group). Rapid H&E staining used a 71 mixture of modified Gill's hematoxylin and alcohol-soluble 1% eosin Y. The staining quality of each section was evaluated and scored. A score of >7 was considered excellent, a score of 6 to 7 good, and a score of ≤5 poor.

RESULTS:

The staining time for rapid staining was approximately 3 minutes, whereas that of routine staining was approximately 12 minutes. There were no significant differences in the staining quality scores or proportions of sections in each grade between the two staining methods. The proportions of sections that were classified as excellent or good were 96.7% and 98.3% for rapid and routine staining, respectively.

CONCLUSIONS:

In frozen breast tissue sections, rapid H&E staining may provide staining quality that is comparable to that of routine staining, while markedly reducing the staining time.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Coloración y Etiquetado / Mama / Eosina Amarillenta-(YS) / Secciones por Congelación / Hematoxilina Límite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: J Int Med Res Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Coloración y Etiquetado / Mama / Eosina Amarillenta-(YS) / Secciones por Congelación / Hematoxilina Límite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: J Int Med Res Año: 2024 Tipo del documento: Article País de afiliación: China
...