Your browser doesn't support javascript.
loading
Pharmacokinetic assessment of low dose decitabine in combination therapies: Development and validation of a sensitive UHPLC-MS/MS method for murine plasma analysis.
Anabtawi, Nadeen; Drabison, Thomas; Jin, Yan; Eisenmann, Eric D; Sparreboom, Alex; Govindarajan, Rajgopal; Baker, Sharyn D; Ahmed, Eman.
Afiliación
  • Anabtawi N; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Drabison T; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Jin Y; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Eisenmann ED; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Sparreboom A; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Govindarajan R; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Baker SD; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA. Electronic address: baker.2480@osu.edu.
  • Ahmed E; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
Article en En | MEDLINE | ID: mdl-38905720
ABSTRACT
Decitabine is a DNA methyltransferase inhibitor used in the treatment of acute myeloid leukemia and myelodysplastic syndrome. The notion that ongoing trials are presently exploring the combined use of decitabine, with or without the cytidine deaminase inhibitor cedazuridine, and other antileukemic drugs necessitates a comprehensive understanding of pharmacokinetic properties and an evaluation of drug-drug interaction liabilities. We report here the development and validation of a sensitive UHPLC-MS/MS method for quantifying decitabine in mouse plasma, which should be useful for such studies. The method involved a one-step protein precipitation extraction, and chromatographic separation on an XBridge HILIC column using gradient elution. The method was found to be robust, accurate, precise, and sufficiently sensitive (lower limit of quantitation, 0.4 ng/mL) to determine decitabine concentrations in microvolumes of plasma from mice receiving the agent orally or intravenously in the presence or absence of cedazuridine.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría de Masas en Tándem / Decitabina Límite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría de Masas en Tándem / Decitabina Límite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos
...