Your browser doesn't support javascript.
loading
[Comparison of open reduction hollow nail anchoring system with loop plate fixation under arthroscopy for the treatment of posterior cruciate ligament avulsion fractures].
Wu, Rong; Zhang, Zhan-Feng; Weng, Wei; Yang, Hong-Hang; Min, Ji-Kang; Sun, Jian-Wei; Shen, Zhe-Yuan.
Afiliación
  • Wu R; Department of Orthopaedics, the First People's Hospital of Huzhou, Huzhou Key Laboratory of Early Diagnosis and Treatment of Osteoarthritis, Huzhou 313000, Zhejiang, China.
  • Zhang ZF; Department of Orthopaedics, the First People's Hospital of Huzhou, Huzhou Key Laboratory of Early Diagnosis and Treatment of Osteoarthritis, Huzhou 313000, Zhejiang, China.
  • Weng W; Department of Orthopaedics, the First People's Hospital of Huzhou, Huzhou Key Laboratory of Early Diagnosis and Treatment of Osteoarthritis, Huzhou 313000, Zhejiang, China.
  • Yang HH; Department of Orthopaedics, the First People's Hospital of Huzhou, Huzhou Key Laboratory of Early Diagnosis and Treatment of Osteoarthritis, Huzhou 313000, Zhejiang, China.
  • Min JK; Department of Orthopaedics, the First People's Hospital of Huzhou, Huzhou Key Laboratory of Early Diagnosis and Treatment of Osteoarthritis, Huzhou 313000, Zhejiang, China.
  • Sun JW; Department of Rehabilitation Medicine, the First People's Hospital of Huzhou, Huzhou 313000, Zhejiang, China.
  • Shen ZY; Department of Orthopaedics, the First People's Hospital of Huzhou, Huzhou Key Laboratory of Early Diagnosis and Treatment of Osteoarthritis, Huzhou 313000, Zhejiang, China.
Zhongguo Gu Shang ; 37(6): 5835-90, 2024 Jun 25.
Article en Zh | MEDLINE | ID: mdl-38910381
ABSTRACT

OBJECTIVE:

To compare clinical effect between open reduction and fixation with cannulated screw and threaded rivet via posteromedial approach versus arthroscopic Endobutton plate fixation in treating posterior cruciate ligament avulsion fractures.

METHODS:

Clinical data of 38 patients with posterior cruciate ligament avulsion fractures from July 2020 to December 2021 were analyzed retrospectively, and divided into open reduction and internal fixation group (posterior medial approach hollow anchor system fixation) and arthroscopic fixation group (Endobutton with loop plate fixation under arthroscopy). There were 20 patients in open reduction and internal fixation group, including 16 males and 4 females, aged from 26 to 74 years old with an average of (42.9±18.8) years old;13 patients on the left side and 7 patients on the right side;12 patients were classified to typeⅡand 8 patiens with type Ⅲ according to Meyers-McKeever fractures classification;14 patients were gradeⅡand 6 patients were grade Ⅲ in back drawer test. There were 18 patients in arthroscopic fixation group, including 11 males and 7 females;aged from 24 to 70 years old with an average of (53.5±13.4) years old;11 patients on the left side and 7 patients on the right side;10 patients were classified to typeⅡand 8 patiens with type Ⅲ according to Meyers-McKeever fractures classification;11 patients were gradeⅡand 7 patients were grade Ⅲ in back drawer test. Operation time, blood loss, and quality of immediate reduction were compared between two groups. Knee range of motion, knee back drawer test, and International Knee Documentation Committee(IKDC) grading, KT2000 stability evaluation and Lysholm function score of knee joint were compared at 6 months after operation.

RESULTS:

All patients were followed up for 8 to 16 months with an average of (12.3±1.9) months. There were no complications such as incision infection, fracture malunion or non-union, and internal fixation loosening occurred. The avulsion fractures of knee joint were reached to imaging healing standard at 6 months after operation. Operation time and blood loss in open reduction and internal fixation group were (56.4±7.1) min and (63.2±10.2) ml, while (89.9±7.4) min and (27.7±8.7) ml in arthroscopic fixation group, respectively, and had significant difference between two groups (P<0.05). There were no differences in immediate reduction quality (χ2=0.257, P=0.612), knee joint range of motion at 6 months after opertaion (t=0.492, P=0.626), knee joint rear drawer test ( χ2=0.320, P=0.572), IKDC classification of knee joint (χ2=0.127, P=0.938), KT2000 stability evaluation (χ2=0.070, P=0.791), and knee Lysholm function score (t=0.092, P=0.282) between two groups.

CONCLUSION:

Posterior medial approach with hollow anchoring system fixation and arthroscopic Endobutton with loop plate fixation for the treatment of posterior cruciate ligament tibial occlusion avulsion fracture could achieve satisfactory clinical results, and arthroscopic surgery has less bleeding, but also has a longer learning curve and longer operation time than traditional incision surgery. The surgeon needs to make a choice according to clinical situation of patient and their own surgical inclination.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artroscopía / Placas Óseas / Ligamento Cruzado Posterior / Fijación Interna de Fracturas Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: Zh Revista: Zhongguo Gu Shang Asunto de la revista: ORTOPEDIA / TRAUMATOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artroscopía / Placas Óseas / Ligamento Cruzado Posterior / Fijación Interna de Fracturas Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: Zh Revista: Zhongguo Gu Shang Asunto de la revista: ORTOPEDIA / TRAUMATOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: China
...