Optimizing the compression resistance of low-nickel stainless steel coronary stents using finite element and response surface methodology.
Wang, Lingling; Wang, Weiqiang; Jiang, Yi; Yuan, Yonghui.
Afiliación
  • Wang L; School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024, China.
  • Wang W; School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024, China. Electronic address: wangwq@dlut.edu.cn.
  • Jiang Y; Dalian Hanzheng Medical Instrument Inspection Co., Ltd, Dalian 116100, China.
  • Yuan Y; Clinical Research Center for Malignant Tumor of Liaoning Province, Cancer Hospital of Dalian University of Technology, Shenyang 110042, China. Electronic address: yyxhdh@126.com.
J Biomech ; 172: 112227, 2024 Jul 11.
Article en En | MEDLINE | ID: mdl-39004042
ABSTRACT
Considering the high strength and excellent biocompatibility of low-nickel stainless steel, this paper focused on optimizing the design of a vascular stent made from this material using finite element analysis (FEA) combined with the response surface methodology (RSM). The aim is to achieve the desired compressive resistance for the stent while maintaining a thin stent wall thickness. The parameters of the stent's support unit width (H), strut width (W), and thickness (T) were selected as input parameters, while the output parameters obtained from FEA included the compressive load, the equivalent plastic strain (PEEQ), axial shortening rate, radial recoil rate, and metal coverage rate. The mathematical models of input parameters and output parameters were established by using the Box Behnken design (BBD) of RSM. The model equations were solved under constrained conditions, and the optimal structural parameters, namely H, W, and T, were finally determined as 0.770 mm, 0.100 mm, and 0.075 mm respectively. In this situation, the compression load of the stent reached the target value of 0.38 N/mm; the PEEQ resulting from the stent expansion was small; the axial shortening, radial recoil, and metal coverage index were all minimized within the required range.