Your browser doesn't support javascript.
loading
Performance evaluation of the new Access HIV Ag/Ab combo assay on the DxI 9000 Access Immunoassay Analyzer.
Lemée, V; Gréaume, S; Gautier, J; Dzamitika, S A; Coignard, C; Jortani, S A; Grillet, B; Badawi, M; Plantier, J-C.
Afiliación
  • Lemée V; CHU Rouen, Department of Virology, National Reference Center of HIV, F-76000 Rouen, France; Univ Rouen Normandie, Univ de Caen, INSERM, DYNAMICURE UMR 1311, CHU Rouen, Department of Virology, National Reference Center of HIV, F-76000 Rouen, France.
  • Gréaume S; Etablissement Français du Sang (EFS) Hauts-de-France - Normandie (HFNO), Bois Guillaume, France.
  • Gautier J; Cerba Xpert, Cergy-Pontoise, France.
  • Dzamitika SA; Cerba Xpert, Cergy-Pontoise, France.
  • Coignard C; Eurofins Biomnis, Ivry-sur-Seine, France.
  • Jortani SA; Kentucky Clinical Trials Laboratory (KCTL), Louisville, KY, USA; University of Louisville School of Medicine, Louisville, KY, USA.
  • Grillet B; Beckman Coulter Immunotech, Marseille, France.
  • Badawi M; Beckman Coulter Immunotech, Marseille, France.
  • Plantier JC; CHU Rouen, Department of Virology, National Reference Center of HIV, F-76000 Rouen, France; Univ Rouen Normandie, Univ de Caen, INSERM, DYNAMICURE UMR 1311, CHU Rouen, Department of Virology, National Reference Center of HIV, F-76000 Rouen, France. Electronic address: jc.plantier@chu-rouen.fr.
J Clin Virol ; 174: 105712, 2024 Oct.
Article en En | MEDLINE | ID: mdl-39047323
ABSTRACT
Fourth-generation HIV immunoassays have been developed to reduce the window period of detection during seroconversion period, allowing for the detection of early and established infections. The aim of this work was to evaluate a newly developed assay, Access HIV Ag/Ab combo on the novel high throughput DxI 9000 Access Immunoassay Analyzer (Beckman Coulter, Inc.). The assay allows for simultaneous qualitative detection and differentiation of HIV-1 p24 antigen and HIV-1/2 antibodies. Assay performance was compared to two gold standard assays, the Abbott Architect HIV Ag/Ab Combo and Roche Elecsys HIV Duo, and assessed in a multicenter study, using a wide panel of samples (n > 9000, clinical samples and viral lysates) representative of genetic diversity for both antibodies and antigens, early phases of infection, negative, and cross-reacting samples. The clinical sensitivity was 100 % for clinical samples as well as for viral lysates. Data on viral lysates and early detection on seroconversion panels showed a better result with the Access assay. Analytical sensitivity showed a limit of p24 detection determined around 0.2 IU/mL. The overall specificity was 99.91 %, and no interference was found using the potentially cross-reactive samples. In conclusion, the Access HIV Ag/Ab combo assay demonstrated its ability for accurate diagnosis of chronic as well as primary HIV infections on the DxI 9000 Analyzer, despite the high level of genetic diversity of these viruses.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Anticuerpos Anti-VIH / Infecciones por VIH / Sensibilidad y Especificidad / VIH-1 / Proteína p24 del Núcleo del VIH Límite: Humans Idioma: En Revista: J Clin Virol Asunto de la revista: VIROLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Anticuerpos Anti-VIH / Infecciones por VIH / Sensibilidad y Especificidad / VIH-1 / Proteína p24 del Núcleo del VIH Límite: Humans Idioma: En Revista: J Clin Virol Asunto de la revista: VIROLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Francia
...