Your browser doesn't support javascript.
loading
Inter-Rater and Intrarater Reliability of Radiographs in the Diagnosis of Pediatric Scaphoid Fractures.
Padeanu, Stefan; Tang, Ken; Highmore, Kerri; Koujok, Khaldoun; Carsen, Sasha; Smit, Kevin; Cheung, Kevin.
Afiliación
  • Padeanu S; University of Ottawa, ON, Canada.
  • Tang K; Children's Hospital of Eastern Ontario Research Institute, Ottawa, Canada.
  • Highmore K; Division of Radiology, Children's Hospital of Eastern Ontario, Ottawa, Canada.
  • Koujok K; Division of Radiology, Children's Hospital of Eastern Ontario, Ottawa, Canada.
  • Carsen S; Division of Orthopaedic Surgery, Children's Hospital of Eastern Ontario, Ottawa, Canada.
  • Smit K; Division of Orthopaedic Surgery, Children's Hospital of Eastern Ontario, Ottawa, Canada.
  • Cheung K; Division of Plastic Surgery, Children's Hospital of Eastern Ontario, Ottawa, Canada.
Hand (N Y) ; : 15589447241257705, 2024 Jul 26.
Article en En | MEDLINE | ID: mdl-39066492
ABSTRACT

BACKGROUND:

Pediatric scaphoid fractures can be challenging to diagnose on plain radiograph. Rates of missed scaphoid fractures can be as high as 30% to 37% on initial imaging and overall sensitivity ranging from 21% to 97%. Few studies, however, have examined the reliability of radiographs in the diagnosis of scaphoid fractures, and none are specific to the pediatric population. Reliability, both between different specialists and for individual raters, may elucidate some of the diagnostic challenges.

METHODS:

We conducted a 2-iteration survey of pediatric orthopedic surgeons, plastic surgeons, radiologists, and emergency physicians at a tertiary children's hospital. Participants were asked to assess 10 series of pediatric wrist radiographs for evidence of scaphoid fracture. Inter-rater and intrarater reliability was calculated using the intraclass correlation coefficient of 2.1.

RESULTS:

Forty-two respondents were included in the first iteration analysis. Inter-rater reliability between surgeons (0.66; 95% confidence interval, 0.43-0.87), radiologists (0.76; 0.55-0.92), and emergency physicians (0.65; 0.46-0.86) was "good" to "excellent." Twenty-six respondents participated in the second iteration for intrarater reliability (0.73; 0.67-0.78). Sensitivity (0.75; 0.69-0.81) and specificity (0.78; 0.71-0.83) of wrist radiographs for diagnosing scaphoid fractures were consistent with results in other studies.

CONCLUSIONS:

Both inter-rater and intrarater reliability for diagnosing pediatric scaphoid fractures on radiographs was good to excellent. No significant difference was found between specialists. Plain radiographs, while useful for obvious scaphoid fractures, are unable to reliably rule out subtle fractures routinely. Our study demonstrates that poor sensitivity stems from the test itself, and not rater variability.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Hand (N Y) Año: 2024 Tipo del documento: Article País de afiliación: Canadá

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Hand (N Y) Año: 2024 Tipo del documento: Article País de afiliación: Canadá
...