Your browser doesn't support javascript.
loading
Effect of surfactant type and concentration on the gas-liquid mass transfer in biotrickling filters used for air pollution control.
Lamprea-Pineda, Paula Alejandra; Carmona, Francisco Javier; Demeestere, Kristof; González-Cortés, Jose Joaquin; Van Langenhove, Herman; Walgraeve, Christophe; Lebrero, Raquel.
Afiliación
  • Lamprea-Pineda PA; Research Group EnVOC, Department of Green Chemistry and Technology, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, 9000, Ghent, Belgium; Institute of Sustainable Processes (ISP), University of Valladolid, C/Dr. Margelina, s/n, 47011, Valladolid, Spain.
  • Carmona FJ; Institute of Sustainable Processes (ISP), University of Valladolid, C/Dr. Margelina, s/n, 47011, Valladolid, Spain; Surfaces and Porous Materials (SMAP), Associated Research Unit to CSIC, University of Valladolid, Paseo Belén 7, E-47011, Valladolid, Spain.
  • Demeestere K; Research Group EnVOC, Department of Green Chemistry and Technology, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, 9000, Ghent, Belgium.
  • González-Cortés JJ; Research Group EnVOC, Department of Green Chemistry and Technology, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, 9000, Ghent, Belgium; Department of Chemical Engineering and Food Technology, Vine and Agri-Food Research Institute (IVAGRO), University of Cádiz, Pol. Río San
  • Van Langenhove H; Research Group EnVOC, Department of Green Chemistry and Technology, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, 9000, Ghent, Belgium.
  • Walgraeve C; Research Group EnVOC, Department of Green Chemistry and Technology, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, 9000, Ghent, Belgium. Electronic address: christophe.walgraeve@ugent.be.
  • Lebrero R; Institute of Sustainable Processes (ISP), University of Valladolid, C/Dr. Margelina, s/n, 47011, Valladolid, Spain. Electronic address: raquel.lebrero@uva.es.
J Environ Manage ; 367: 121968, 2024 Sep.
Article en En | MEDLINE | ID: mdl-39068787
ABSTRACT
Volatile organic compounds (VOCs) emitted into the atmosphere negatively affect the environment and human health. Biotrickling filtration, an effective technology for treating VOC-laden waste gases, faces challenges in removing hydrophobic VOCs due to their low water solubility and therefore limited bioavailability to microorganisms. Consequently, the addition of (bio)surfactants has proven to be a promising strategy to enhance the removal of hydrophobic VOCs in biotrickling filters (BTFs). Yet, up to now, no single study has ever performed a mass transfer characterization of a BTF under (bio)surfactants addition. In this study, the effect of (bio)surfactant addition on the gas-liquid mass transfer characteristics of two BTFs was measured by using oxygen (O2) as a model gas. Through an empirical correlation, the mass transfer coefficients (kLa) of two hydrophobic VOCs, toluene and hexane, which are of industrial and environmental significance, were estimated. One BTF was filled with expanded perlite, while the other with a mixture of compost and wood chips (C + WC). Both BTFs were operated under different liquid velocities (UL 0.95 and 1.53 m h-1). Saponin, a biological surfactant, and Tween 80, a synthetic surfactant, were added to the recirculating liquid at different critical micelle concentrations (CMCs 0-3 CMC). The higher interfacial and surface area of the perlite BTF compared to the C + WC BTF led to higher kLaO2 values regardless of the operational condition 308 ± 18-612 ± 19 h-1 versus 42 ± 4-177 ± 24 h-1, respectively. Saponin addition at 0.5 and 1 CMC had positive effects on the perlite BTF, with kLaO2 values two times higher compared to those at 0 CMC. Tween 80 exhibited a neutral or slightly positive effect on the mass transfer of both BTFs under all conditions. Overall, the CMC, along with the physical characteristics of the packing materials and the operational conditions evaluated explained the results obtained. This study provides fundamental data essential to improve the performance and design of BTFs for hydrophobic VOCs abatement.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tensoactivos / Contaminación del Aire / Compuestos Orgánicos Volátiles / Filtración Idioma: En Revista: J Environ Manage Año: 2024 Tipo del documento: Article País de afiliación: España

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tensoactivos / Contaminación del Aire / Compuestos Orgánicos Volátiles / Filtración Idioma: En Revista: J Environ Manage Año: 2024 Tipo del documento: Article País de afiliación: España
...