An excimer process induced a turn-on fluorescent probe for detection of ultra-low concentration of mercury ions.
Fang, Shujing; Swamy, K M K; Zan, Wen-Yan; Yoon, Juyoung; Liu, Shudi.
Afiliación
  • Fang S; College of Chemistry and Chemical Engineering, Yantai University, Yantai 264005, P. R. China. liushd2018@163.com.
  • Swamy KMK; Department of Chemistry and Nanoscience, Ewha Womans University, Seoul, 03760, Korea. jyoon@ewha.ac.kr.
  • Zan WY; Institute of Molecular Science, Shanxi University, Taiyuan, 030006, P. R. China.
  • Yoon J; Department of Chemistry and Nanoscience, Ewha Womans University, Seoul, 03760, Korea. jyoon@ewha.ac.kr.
  • Liu S; College of Chemistry and Chemical Engineering, Yantai University, Yantai 264005, P. R. China. liushd2018@163.com.
J Mater Chem B ; 12(34): 8376-8382, 2024 Aug 28.
Article en En | MEDLINE | ID: mdl-39109420
ABSTRACT
The accumulation of mercury pollution in plants can induce severe injury to human beings. It is a great challenge to monitor ultra-low concentrations of mercury in complicated matrixes. In this study, we successfully developed a strategy via Hg2+-triggered naphthalene-based fluorescent probe 1, which formed excimer that subsequently emitted fluorescence for the successful detection of ultra-low concentrations of Hg2+. The coordination of N and S atoms with Hg2+ facilitated the formation of excimer from the naphthalene-conjugated planes that were in sufficiently close proximity. Suppression of CN bond rotation also induced the chelation-enhanced fluorescence (CHEF) effect, and the cumulative result of these effects was obvious fluorescent enhancement. Compared with probe 2, the other key factor for detection of Hg2+ is that the electrons of the hydroxyl group can easily transfer to a naphthalene moiety, resulting in an augmented π-electron density that enhanced the π-π stacking of the naphthalene-conjugated excimer. After detailed spectral studies and mechanism discussions, it was realized that probe 1 was able to detect ultra-low concentrations of Hg2+ in PBS buffer solution. The detection limit was calculated to be 1.98 nM. On account of the excellent performances, the probe was successfully applied in monitoring Hg2+ in water and pea sprouts with the potential for application as an advanced warning of contamination.