Your browser doesn't support javascript.
loading
Primate Eye Tracking with Carbon-Nanotube-Paper-Composite Based Capacitive Sensors and Machine Learning Algorithms.
Li, Tianyi; Sakthivelpathi, Vigneshwar; Qian, Zhongjie; Soetedjo, Robijanto; Chung, Jae-Hyun.
Afiliación
  • Li T; Mechanical Engineering, University of Washington, Seattle, WA, 98195, USA.
  • Sakthivelpathi V; Mechanical Engineering, University of Washington, Seattle, WA, 98195, USA.
  • Qian Z; Mechanical Engineering, University of Washington, Seattle, WA, 98195, USA.
  • Soetedjo R; Department of Physiology and Biophysics, University of Washington, Seattle, WA, 98195, USA; Washington National Primate Research Center, University of Washington, Seattle, WA 98195, USA.
  • Chung JH; Mechanical Engineering, University of Washington, Seattle, WA, 98195, USA. Electronic address: jae71@uw.edu.
J Neurosci Methods ; : 110249, 2024 Aug 14.
Article en En | MEDLINE | ID: mdl-39151657
ABSTRACT

BACKGROUND:

Accurate real-time eye tracking is crucial in oculomotor system research. While the scleral search coil system is the gold standard, its implantation procedure and bulkiness pose challenges. Camera-based systems are affected by ambient lighting and require high computational and electric power. New Method This study presents a novel eye tracker using proximity capacitive sensors made of carbon-nanotube-paper-composite (CPC). These sensors detect femtofarad-level capacitance changes caused by primate corneal movement during horizontal and vertical eye rotations. Data processing and machine learning algorithms are evaluated to enhance the accuracy of gaze angle prediction.

RESULTS:

The system performance is benchmarked against the scleral coil during smooth pursuits, saccades tracking, and fixations. The eye tracker demonstrates up to 0.97 correlation with the coil in eye tracking and is capable of estimating gaze angle with a median absolute error as low as 0.30°. Comparison The capacitive eye tracker demonstrates good consistency and accuracy in comparison to the gold-standard scleral search coil method.

CONCLUSIONS:

This lightweight, non-invasive capacitive eye tracker offers potential as an alternative to traditional coil and camera-based systems in oculomotor research and vision science.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Neurosci Methods Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Neurosci Methods Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos
...