Poisson function and volume ratio of soft anisotropic materials under large deformations.
Filho, J C A D; Nunes, L C S.
Afiliación
  • Filho JCAD; Laboratory of Opto-Mechanics (LOM), Department of Mechanical Engineering (PGMEC-TEM), Universidade Federal Fluminense - UFF, Rua Passo da Pátria, 156, Bloco E, Sala 210, Niterói, RJ, CEP 24210-240, Brazil.
  • Nunes LCS; Laboratory of Opto-Mechanics (LOM), Department of Mechanical Engineering (PGMEC-TEM), Universidade Federal Fluminense - UFF, Rua Passo da Pátria, 156, Bloco E, Sala 210, Niterói, RJ, CEP 24210-240, Brazil. Electronic address: luizcsn@id.uff.br.
J Mech Behav Biomed Mater ; 158: 106689, 2024 Aug 15.
Article en En | MEDLINE | ID: mdl-39153409
ABSTRACT
Accurate transverse deformation measurements are required for the estimation of the Poisson function and volume ratio. In this study, pure silicone and soft composite specimens were subjected to uniaxial tension, and the digital image correlation method was used to measure longitudinal and in- and out-of-plane transverse stretches. To minimize the effects of measurement errors on parameter estimation, the measured transverse stretches were defined in terms of the longitudinal stretch using a new formulation based on Poisson's ratios and two stretch-dependent parameters. From this formulation, Poisson functions and volume ratio for soft materials under large deformations were obtained. The results showed that pure silicone can be considered isotropic and nearly incompressible under large deformations, as expected. In contrast, Poisson's ratio of silicone reinforced with extensible fabric can exceed classical bounds, including negative value (auxetic behavior). The incompressibility assumption can be employed for describing the stress-stretch curve of pure silicone, while volume ratios are required for soft composites. Data of human skin, aortic wall, and annulus fibrosus from the literature were selected and analyzed. Except for the aortic wall, which can be considered nearly incompressible, the studied soft tissues must be regarded as compressible. All tissues presented anisotropic behavior.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Mech Behav Biomed Mater Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article País de afiliación: Brasil

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Mech Behav Biomed Mater Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article País de afiliación: Brasil
...