Your browser doesn't support javascript.
loading
An Exploration of Dissolution Tests for Inhalation Aerosols.
Wang, Min; Fang, Zhaoying; Yang, Kunhao; Guo, Xiaowei; Li, Shangyang; Liu, Ali.
Afiliación
  • Wang M; School of Pharmacy, Shandong University of Traditional Chinese Medicine, Shandong, China.
  • Fang Z; Shandong Engineering Research Center for New Drug Pharmaceuticals R&D, Linyi, Shandong, China.
  • Yang K; Lunenbetter R&D Center, No.243 Yinquashan Road, Lanshan District, Linyi, Shandong, China.
  • Guo X; Shandong Engineering Research Center for New Drug Pharmaceuticals R&D, Linyi, Shandong, China.
  • Li S; Lunenbetter R&D Center, No.243 Yinquashan Road, Lanshan District, Linyi, Shandong, China.
  • Liu A; Shandong Engineering Research Center for New Drug Pharmaceuticals R&D, Linyi, Shandong, China.
AAPS PharmSciTech ; 25(7): 230, 2024 Oct 01.
Article en En | MEDLINE | ID: mdl-39354249
ABSTRACT
This study aimed to establish a feasible dissolution method for inhalation aerosols. A method of collecting fine particles was investigated to capture aerosol particles less than 4 µm in diameter for dissolution tests. This dose collection method enabled the aerosol particles to be uniformly distributed on the glass fiber filter, thus considerably reducing particle agglomeration. Budesonide was used as a model drug. The aerodynamic particle size distribution (APSD) of the meter-dose inhaler (MDI) was compared by replacing actuators with different orifice sizes. Dissolution tests were conducted on fine particle doses collected using various actuators, and the dissolution profiles were modeled. The fine particle dose decreased with an increasing orifice size of the actuator. Actuators with different orifice sizes would affect the dissolution behavior of inhaled drugs. This finding was supported by similarity factor f2 analysis, suggesting the dissolution method has a discriminative capacity. The results of various model fits showed that the dissolution profiles produced by the different actuators could be fitted well using the Weibull mathematical model. The method employed in this study could offer a potential avenue for exploring the relationship between the orifice size of the actuator and the dissolution behavior of inhaled corticosteroids. This dissolution method was simple, reproducible, and suitable for determining the dissolution of inhalation aerosols.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tamaño de la Partícula / Solubilidad / Budesonida / Aerosoles Idioma: En Revista: AAPS PharmSciTech Asunto de la revista: FARMACOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tamaño de la Partícula / Solubilidad / Budesonida / Aerosoles Idioma: En Revista: AAPS PharmSciTech Asunto de la revista: FARMACOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: China
...