The influence of target thickness and backstop material on proton-produced neutron beams for radiotherapy.
Med Phys ; 7(5): 495-502, 1980.
Article en En | MEDLINE | ID: mdl-6252431
ABSTRACT
Results are presented of measurements of skin sparing, penetration and total dose per unit of incident charge for various target thicknesses and filtrations for a neutron beam generated by 42 MeV protons on beryllium. These results are contrasted to predictions outlined in a previous paper. The differences from these predictions are attributed to the contribution of low-energy neutrons produced by the residual proton beam in the thick copper target backstop.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radioterapia / Análisis por Activación / Análisis de Activación de Neutrones Límite: Humans Idioma: En Revista: Med Phys Año: 1980 Tipo del documento: Article