Determination of hexahydrophthalic acid and methylhexahydrophthalic acid in plasma after derivatisation with pentafluorobenzyl bromide using gas chromatography and mass spectrometric detection.
J Chromatogr B Biomed Sci Appl
; 691(2): 331-9, 1997 Apr 11.
Article
en En
| MEDLINE
| ID: mdl-9174269
A method for the simultaneous determination of hexahydrophthalic acid (HHP acid) and methylhexahydrophthalic acid (MHHP acid) in human plasma was developed. The procedure was a rapid, single step extractive derivatisation with pentafluorobenzyl bromide as the derivatisation agent. The formed pentafluorobenzyl esters were analysed by gas chromatography-mass spectrometry in negative ion chemical ionisation mode with ammonia as the moderating gas. Deuterium-labeled HHP acid and MHHP acid were used as internal standards. The detection limit was 0.4 ng/ml for HHP acid (m/z 153) and 0.3 ng/ml for MHHP acid (m/z 365). The within-day precision of the method was between 2 and 3% and the between-day precision was between 3 and 12%. The overall recovery was between 65 and 83%. A comparison between HHP acid determinations with a previous and this method showed that the methods gave similar results. The method was applicable for analysis of plasma from occupationally exposed workers.