Your browser doesn't support javascript.
loading
Diagnostic value of two rapid and individual D-dimer assays in patients with clinically suspected pulmonary embolism: comparison with microplate enzyme-linked immunosorbent assay.
Meyer, G; Fischer, A M; Collignon, M A; Benazzouz, A; Monge, F; Sors, H; de Raucourt, E.
Afiliación
  • Meyer G; Service de Pneumologie-Réanimation, Hopital Laennec, Université Paris V, France.
Blood Coagul Fibrinolysis ; 9(7): 603-8, 1998 Oct.
Article en En | MEDLINE | ID: mdl-9863708
ABSTRACT
A semiquantitative enzyme-linked immunosorbent assay (ELISA) test (Instant IA D-dimer) and a new quantitative rapid and individual test (STA-Liatest DDi) were compared with the reference microplate ELISA (Asserachrom D-Di) for D-dimer testing in 142 patients clinically suspected of pulmonary embolism, on the basis of clinical symptoms and signs, electrocardiogram, blood gases and chest X-Ray abnormalities. The cut-off value for the quantitative tests was 500 ng/ml and Instant IA was interpreted by three readers. Pulmonary embolism was confirmed by lung scan or angiography in 60 patients (42%). The sensitivities of ELISA and STA-Liatest DDi were 92% [95% confidence interval (CI) 82-97%] and 93% (95% CI 84-98%), respectively. The three readings of Instant IA D-dimer disagreed in 27 (19%) of the patients and sensitivity varied from 83 to 93% according to the readers. In the 115 patients with concordant readings, sensitivity was 92% (95% CI 82-98%). These results suggest that STA Liatest DDi may be used instead of microplate ELISA for the exclusion of pulmonary embolism, whereas the use of Instant IA D-dimer for this purpose is limited by the number of discordant results.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Embolia Pulmonar / Productos de Degradación de Fibrina-Fibrinógeno Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Blood Coagul Fibrinolysis Asunto de la revista: ANGIOLOGIA / HEMATOLOGIA Año: 1998 Tipo del documento: Article País de afiliación: Francia
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Embolia Pulmonar / Productos de Degradación de Fibrina-Fibrinógeno Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Blood Coagul Fibrinolysis Asunto de la revista: ANGIOLOGIA / HEMATOLOGIA Año: 1998 Tipo del documento: Article País de afiliación: Francia
...