Your browser doesn't support javascript.
loading
Species-specific isotope dilution analysis of mono-, di, and tri-butyltin compounds in sediment using gas chromatography-inductively coupled plasma mass spectrometry with synthesized 118Sn-enriched butyltins.
Inagaki, Kazumi; Takatsu, Akiko; Watanabe, Takuro; Aoyagi, Yoshie; Okamoto, Kensaku.
Afiliação
  • Inagaki K; Environmental Standards Section, National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki 305-8563, Japan.
Analyst ; 128(3): 265-72, 2003 Mar.
Article em En | MEDLINE | ID: mdl-12705386
A species-specific isotope dilution (ID) method is described for the determination of mono-, di, and tri-butyltin compounds in sediment by gas chromatography-inductively coupled plasma mass spectrometry (GC-ICP-MS), where the mixture of 118Sn-enriched butyltin compounds synthesized in our laboratory was used as a spike. A correction method for the mass bias, a quantitative extraction of the butyltins from sediment, and an assay for the concentration of the standard solution for the reverse ID procedure were investigated to achieve a reliable ID analysis. The spike solution was added with tri-propyltin (TPrT), and the butyltins were extracted by mechanical shaking into acetic acid-tropolone-toluene. The extracted butyltins were ethylated with sodium tetraethylborate and measured by GC-ICP-MS. The mass bias correction factor for the butyltins was calculated with the measured area ratio of 120Sn/118Sn of TPrT in each chromatographic run, and the correction was carried out. The mass bias was well corrected with this in-run correction (the standard uncertainties of the corrected 120Sn/118Sn for the butyltins were in the range 0.03-0.45%, typically 0.25%, with triplicate measurement corresponding to 0.02-0.37% mass bias). The extraction efficiency of mono-butyltin (MBT) from sediment was improved by using tropolone-toluene as the solvent. Well-defined standard solutions for the reverse-ID procedure could be obtained by an assay for the purities of the natural abundance butyltin chloride reagents used for preparing the standard solutions. Overall uncertainties associated with the present method were estimated, where the sediment certified reference materials, PACS-2 and BCR 646, were analyzed. The uncertainty arising from the extraction was the main contributor to the overall uncertainties for MBT and di-butyltin (DBT) determinations, while with the case of tri-butyltin (TBT) determination the uncertainties arising from the purity of TBT chloride reagent used for preparing the standard solution was a large contributor to the overall uncertainties although the uncertainty arising from the extraction was also a main contributor. The analytical results of MBT, DBT, and TBT in both reference materials, except for MBT results in PACS-2, were in good agreement with the certified values in each. The result of MBT in PACS-2 (0.677 +/- 0.049 microg g(-1) as tin, mean +/- expanded uncertainty) was significantly higher than the certified value (0.45 +/- 0.05 microg g(-1)), but closely matched with the lately reported values (Rajendran, Tao, Nakazato and Miyazaki, Analyst, 2000, 125, 1757: 0.62 +/- 0.02 microg g(-1); Chiron, Roy, Cottier and Jeannot, J. Chromatogr. A, 2000, 879, 137: 0.634 +/- 0.082 microg g(-1); Alonso, Encinar, Gonzalez and Sanz-Medal, Anal. Bioanal. Chem., 2002, 373, 432: 0.64 +/- 0.04 microg g(-1). The present method is concluded to be reliable for the determination of MBT, DBT, and TBT in sediment.
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Analyst Ano de publicação: 2003 Tipo de documento: Article País de afiliação: Japão
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Analyst Ano de publicação: 2003 Tipo de documento: Article País de afiliação: Japão
...