Your browser doesn't support javascript.
loading
Three-dimensional echocardiographic volume computation by polyhedral surface reconstruction: in vitro validation and comparison to magnetic resonance imaging.
Gopal, A S; King, D L; Katz, J; Boxt, L M; King, D L; Shao, M Y.
Afiliação
  • Gopal AS; Department of Radiology, Columbia University, New York, NY 10032.
J Am Soc Echocardiogr ; 5(2): 115-24, 1992.
Article em En | MEDLINE | ID: mdl-1571165
Two-dimensional echocardiographic methods of left ventricular volume computation are limited by geometric assumptions and image plane positioning error in the nonvisualized dimension. We evaluated a three-dimensional (3D echocardiographic method that addresses these limitations. Our method uses a volume computation algorithm based on polyhedral surface reconstruction (PSR) and nonparallel, unequally spaced, nonintersecting short-axis planes. Seventeen balloon phantoms were subjected to volume computation by the 3D echocardiography-PSR method and by magnetic resonance imaging (MRI) and compared to true volumes determined by water displacement. The results for 3D echocardiography-PSR were: accuracy = 2.27%, interobserver variability = 4.33%, r = 0.999, SEE = 2.45 ml, and p less than 0.001. Results for MRI were 8.01%, 13.78%, r = 0.995, SEE = 7.01 ml, and p less than 0.001. There was no statistically significant difference between the methods. We conclude that precise image plane positioning and use of the 3D echocardiographic-PSR volume computation method achieves high accuracy and reproducibility in vitro. The excellent in vitro correlation between 3D echocardiography-PSR and MRI indicates that MRI may also serve as an in vivo standard of comparison.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Ecocardiografia / Volume Cardíaco Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Am Soc Echocardiogr Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 1992 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Ecocardiografia / Volume Cardíaco Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Am Soc Echocardiogr Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 1992 Tipo de documento: Article
...