Your browser doesn't support javascript.
loading
Experimental determination of electron source parameters for accurate Monte Carlo calculation of large field electron therapy.
Huang, Vicky W; Seuntjens, Jan; Devic, Slobodan; Verhaegen, Frank.
Afiliação
  • Huang VW; Medical Physics Unit, McGill University, 1650 Cedar Ave Montreal, Quebec H3G 1A4, Canada. vhuang@po-box.mcgill.ca
Phys Med Biol ; 50(5): 779-86, 2005 Mar 07.
Article em En | MEDLINE | ID: mdl-15798254
ABSTRACT
Extensive work has been performed to validate Monte Carlo models for both photon and electron beams under standard conditions. However, for large field electron beam therapy, Monte Carlo simulations have not been able to provide good agreement when compared to the measured dose distributions. Since the accuracy of the calculation relies heavily on the geometry parameters of the linear accelerator and the characteristics of the incident electron beam, it is crucial to have a complete comprehension of these independent factors. In this work, the electron focal spot size for a CL21EX linac with various energies (6, 9, 12 and 16 MeV) was measured with a slit camera composed of alternating lead and paper sheets. For all the energies investigated, the electron focal spot is found to be elliptical and has a full width at half maximum (FWHM) ranging from 1.69 mm to 2.24 mm. A shift with respect to the crosshair was associated with each measured focal spot. In addition, we present an improved result for the large field in-air profile by utilizing a proposed divergent beam model in conjunction with the experimental focal spot dimension. This model can potentially provide a solution to the Monte Carlo validation of large field electron beam therapy.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 1_ASSA2030 Problema de saúde: 1_financiamento_saude Assunto principal: Aceleradores de Partículas / Planejamento da Radioterapia Assistida por Computador / Radioterapia de Alta Energia Tipo de estudo: Health_economic_evaluation / Prognostic_studies Idioma: En Revista: Phys Med Biol Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Canadá
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 1_ASSA2030 Problema de saúde: 1_financiamento_saude Assunto principal: Aceleradores de Partículas / Planejamento da Radioterapia Assistida por Computador / Radioterapia de Alta Energia Tipo de estudo: Health_economic_evaluation / Prognostic_studies Idioma: En Revista: Phys Med Biol Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Canadá
...