Your browser doesn't support javascript.
loading
[Amperometric biosensor for ethanol analysis in wines and grape must during wine fermentation].
Ukr Biokhim Zh (1999) ; 77(1): 96-103, 2005.
Article em Uk | MEDLINE | ID: mdl-16335276
ABSTRACT
The amperometric biosensor for ethanol determination based on alcohol oxidase immobilised by the method of electrochemical polymerization has been developed. The industrial screen-printed platinum electrodes were used as transducers for creation of amperometric alcohol biosensor. Optimal conditions for electrochemical deposition of an active membrane with alcohol oxidase has been determined. Biosensors are characterised by good reproducibility and operational stability with minimal detection limit of ethanol 8 x 10(-5) M. The good correlation of results for ethanol detection in wine and during wine fermentation by using the developed amperometric biosensor with the data obtained by the standard methods was shown (r = 0.995).
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vinho / Técnicas Biossensoriais / Etanol / Fermentação Idioma: Uk Revista: Ukr Biokhim Zh (1999) Ano de publicação: 2005 Tipo de documento: Article
Buscar no Google