Your browser doesn't support javascript.
loading
[Anatomic evaluation the entry point of C2 pedicle screw].
Ma, Xiang-yang; Yin, Qing-shui; Wu, Zeng-hui; Xia, Hong; Zhong, Shi-zhen; Liu, Jing-fa; Xu, Da-chuan.
Afiliação
  • Ma XY; Department of Orthopaedics, Guangzhou General Hospital of Guangzhou Military Command, Guangzhou 510010, China. maxy1001@sina.com
Zhonghua Wai Ke Za Zhi ; 44(8): 562-4, 2006 Apr 15.
Article em Zh | MEDLINE | ID: mdl-16784639
OBJECTIVE: To study the relevant position of C(2) pedicle to C(2) inferior articular process, set up a technique of C(2) pedicle screw placement with the inferior articular process of axis as an anatomic landmark. METHODS: Fifty C(2) bone specimens were used to measure the distance from the sagittal midline to the medial border, the midpoint and the lateral border of C(2) inferior articular process or C(2) pedicle; the width and the height of the C(2) pedicle were also evaluated. The anatomic relation between the measurements data of C(2) pedicle and that of C(2) inferior articular process were analyzed, and the technique of C(2) pedicle screw fixation was established. RESULTS: The medial border of C(2) inferior articular process was averaged (3.67 +/- 0.41) mm lateral to that of C(2) pedicle, and the midpoint C(2) inferior articular process was averaged (1.15 +/- 0.44) mm lateral to the lateral border of C(2) pedicle, respectively. Using the C(2) inferior articular process as landmark, two techniques was established for C(2) pedicle screw placement. The entry point of method A was located in 2 mm medial and superior to the central point of C(2) inferior articular process; the entry point of method B was at the crossing point of the medial border C(2) inferior articular process with the superior quarter of C(2) inferior articular process. CONCLUSIONS: There is a steady anatomic relation between C(2) pedicle and C(2) inferior articular process, the C(2) inferior articular process could be as a convenient key anatomic landmark to determine the location of C(2) pedicle and the position of C(2) pedicle screw entry point.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vértebra Cervical Áxis Limite: Humans Idioma: Zh Revista: Zhonghua Wai Ke Za Zhi Ano de publicação: 2006 Tipo de documento: Article País de afiliação: China
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vértebra Cervical Áxis Limite: Humans Idioma: Zh Revista: Zhonghua Wai Ke Za Zhi Ano de publicação: 2006 Tipo de documento: Article País de afiliação: China
...