The obstacles to maximising the impact of public access defibrillation: an assessment of the dispatch mechanism for out-of-hospital cardiac arrest.
Cairns, K J; Hamilton, A J; Marshall, A H; Moore, M J; Adgey, A A J; Kee, F.
Afiliação
  • Cairns KJ; Centre for Statistical Science and Operational Research (CenSSOR), Sir David Bates Building, Queen's University Belfast, UK. k.cairns@qub.ac.uk
Heart ; 94(3): 349-53, 2008 Mar.
Article em En | MEDLINE | ID: mdl-17540690
OBJECTIVES: To determine the diagnostic accuracy of advanced medical priority dispatch system (AMPDS) software used to dispatch public access defibrillation first responders to out-of-hospital cardiac arrests (OHCA). DESIGN: All true OHCA events in North and West Belfast in 2004 were prospectively collated. This was achieved by a comprehensive search of all manually completed Patient Report Forms compiled by paramedics, together with autopsy reports, death certificates and medical records. The dispatch coding of all emergency calls by AMPDS software was also obtained for the same time period and region, and a comparison was made between these two datasets. SETTING: A single urban ambulance control centre in Northern Ireland. POPULATION: All 238 individuals with a presumed or actual OHCA in the North and West Belfast Health and Social Services Trust population of 138 591 (2001 Census), as defined by the Utstein Criteria. MAIN OUTCOME MEASURES: The accurate dispatch of an emergency ambulance to a true OHCA. RESULTS: The sensitivity of the dispatch mechanism for detecting OHCA was 68.9% (115/167, 95% confidence interval (CI) 61.3% to 75.8%). However, the sensitivity for arrests with ventricular fibrillation (VF) was 44.4% (12/27) with sensitivity for witnessed VF of 47.1% (8/17). The positive predictive value was 63.5% (115/181, 95% CI 56.1% to 70.6%). CONCLUSIONS: The sensitivity of this dispatch process for cardiac arrest is moderate and will constrain the effectiveness of Public Access Defibrillation (PAD) schemes which utilise it. TRIAL REGISTRATION: controlled-trials.com ISRCTN07286796.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 11_ODS3_cobertura_universal / 2_ODS3 / 6_ODS3_enfermedades_notrasmisibles Problema de saúde: 11_delivery_arrangements / 2_cobertura_universal / 6_cardiovascular_diseases Assunto principal: Software / Cardioversão Elétrica / Reanimação Cardiopulmonar / Sistemas de Comunicação entre Serviços de Emergência / Acessibilidade aos Serviços de Saúde / Parada Cardíaca Tipo de estudo: Evaluation_studies / Prognostic_studies Aspecto: Determinantes_sociais_saude Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Heart Assunto da revista: CARDIOLOGIA Ano de publicação: 2008 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 11_ODS3_cobertura_universal / 2_ODS3 / 6_ODS3_enfermedades_notrasmisibles Problema de saúde: 11_delivery_arrangements / 2_cobertura_universal / 6_cardiovascular_diseases Assunto principal: Software / Cardioversão Elétrica / Reanimação Cardiopulmonar / Sistemas de Comunicação entre Serviços de Emergência / Acessibilidade aos Serviços de Saúde / Parada Cardíaca Tipo de estudo: Evaluation_studies / Prognostic_studies Aspecto: Determinantes_sociais_saude Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Heart Assunto da revista: CARDIOLOGIA Ano de publicação: 2008 Tipo de documento: Article
...