High-resolution intracranial MRA at 7T using autocalibrating parallel imaging: initial experience in vascular disease patients.
von Morze, Cornelius; Purcell, Derk D; Banerjee, Suchandrima; Xu, Duan; Mukherjee, Pratik; Kelley, Douglas A; Majumdar, Sharmila; Vigneron, Daniel B.
Afiliação
  • von Morze C; Department of Radiology, University of California, San Francisco, CA 94143-2512, USA.
Magn Reson Imaging ; 26(10): 1329-33, 2008 Dec.
Article em En | MEDLINE | ID: mdl-18508216
ABSTRACT

PURPOSE:

Greater spatial resolution in intracranial three-dimensional time-of-flight (TOF) magnetic resonance angiography (MRA) is possible at higher field strengths, due to the increased contrast-to-noise ratio (CNR) from the higher signal-to-noise ratio and the improved background suppression. However, at very high fields, spatial resolution is limited in practice by the acquisition time required for sequential phase encoding. In this study, we applied parallel imaging to 7T TOF MRA studies of normal volunteers and patients with vascular disease, in order to obtain very high resolution (0.12 mm(3)) images within a reasonable scan time. MATERIALS AND

METHODS:

Custom parallel imaging acquisition and reconstruction methods were developed for 7T MRA, based on generalized autocalibrating partially parallel acquisition (GRAPPA). The techniques were compared and applied to studies of seven normal volunteers and three patients with cerebrovascular disease.

RESULTS:

The technique produced high resolution studies free from discernible reconstruction artifacts in all subjects and provided excellent depiction of vascular pathology in patients.

CONCLUSIONS:

7T TOF MRA with parallel imaging is a valuable noninvasive angiographic technique that can attain very high spatial resolution.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transtornos Cerebrovasculares / Angiografia por Ressonância Magnética Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: Magn Reson Imaging Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transtornos Cerebrovasculares / Angiografia por Ressonância Magnética Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: Magn Reson Imaging Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Estados Unidos
...