Your browser doesn't support javascript.
loading
Physics process level discrimination of detections for GATE: assessment of contamination in SPECT and spurious activity in PET.
De Beenhouwer, Jan; Staelens, Steven; Vandenberghe, Stefaan; Verhaeghe, Jeroen; Van Holen, Roel; Rault, Erwann; Lemahieu, Ignace.
Afiliação
  • De Beenhouwer J; Department of Electronics and Information Systems, MEDISIP, Ghent University-IBBT-IBiTech, De Pintelaan 185 Block B, B-9000 Ghent, Belgium. jan.debeenhouwer@ugent.be
Med Phys ; 36(4): 1053-60, 2009 Apr.
Article em En | MEDLINE | ID: mdl-19472610
ABSTRACT
The GEANT4 application for tomographic emission (GATE) is one of the most detailed Monte Carlo simulation tools for SPECT and PET. It allows for realistic phantoms, complex decay schemes, and a large variety of detector geometries. However, only a fraction of the information in each particle history is available for postprocessing. In order to extend the analysis capabilities of GATE, a flexible framework was developed. This framework allows all detected events to be subdivided according to their type In PET, true coincidences from others, and in SPECT, geometrically collimated photons from others. The framework of the authors can be applied to any isotope, phantom, and detector geometry available in GATE. It is designed to enhance the usability of GATE for the study of contamination and for the investigation of the properties of current and future prototype detectors. The authors apply the framework to a case study of Bexxar, first assuming labeling with 124I, then with 131I. It is shown that with 124I PET, results with an optimized window improve upon those with the standard window but achieve less than half of the ideal improvement. Nevertheless, 124I PET shows improved resolution compared to 131I SPECT with triple-energy-window scatter correction.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada de Emissão de Fóton Único / Tomografia por Emissão de Pósitrons Tipo de estudo: Health_economic_evaluation / Prognostic_studies Limite: Humans Idioma: En Revista: Med Phys Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Bélgica
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada de Emissão de Fóton Único / Tomografia por Emissão de Pósitrons Tipo de estudo: Health_economic_evaluation / Prognostic_studies Limite: Humans Idioma: En Revista: Med Phys Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Bélgica
...