Your browser doesn't support javascript.
loading
Development and irradiation test of lost alpha detection system for ITER.
Nishiura, M; Nagasaka, T; Fujioka, K; Fujimoto, Y; Tanaka, T; Ido, T; Yamamoto, S; Kashiwa, S; Sasao, M.
Afiliação
  • Nishiura M; National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292, Japan. nishiura@nifs.ac.jp
Rev Sci Instrum ; 81(10): 10D313, 2010 Oct.
Article em En | MEDLINE | ID: mdl-21033839
ABSTRACT
We developed a lost alpha detection system to use in burning plasma experiments. The scintillators of AgZnS and polycrystalline CeYAG were designed for a high-temperature environment, and the optical transmission line was designed to transmit from the scintillator to the port plug. The required optical components of lenses and mirrors were irradiated using the fission reactor with the initial result that there was no clear change after the irradiation with a neutron flux of 9.6×10(17) nm(-2) s(-1) for 48 h. We propose a diagnostic of alpha particle loss, so-called alpha particle induced gamma ray spectroscopy. The initial laboratory test has been carried out by the use of the Ce doped Lu(2)SiO(5) scintillator detector and an Am-Be source to detect the 4.44 MeV high energy gamma ray due to the (9)Be(α,nγ)(12)C reaction.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Japão
...