Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection.
Moscariello, Antonio; Takx, Richard A P; Schoepf, U Joseph; Renker, Matthias; Zwerner, Peter L; O'Brien, Terrence X; Allmendinger, Thomas; Vogt, Sebastian; Schmidt, Bernhard; Savino, Giancarlo; Fink, Christian; Bonomo, Lorenzo; Henzler, Thomas.
Afiliação
  • Moscariello A; Heart & Vascular Center, Medical University of South Carolina, Charleston, SC 29425-2260, USA.
Eur Radiol ; 21(10): 2130-8, 2011 Oct.
Article em En | MEDLINE | ID: mdl-21611758
OBJECTIVES: To compare image noise, image quality and diagnostic accuracy of coronary CT angiography (cCTA) using a novel iterative reconstruction algorithm versus traditional filtered back projection (FBP) and to estimate the potential for radiation dose savings. METHODS: Sixty five consecutive patients (48 men; 59.3 ± 7.7 years) prospectively underwent cCTA and coronary catheter angiography (CCA). Full radiation dose data, using all projections, were reconstructed with FBP. To simulate image acquisition at half the radiation dose, 50% of the projections were discarded from the raw data. The resulting half-dose data were reconstructed with sinogram-affirmed iterative reconstruction (SAFIRE). Full-dose FBP and half-dose iterative reconstructions were compared with regard to image noise and image quality, and their respective accuracy for stenosis detection was compared against CCA. RESULTS: Compared with full-dose FBP, half-dose iterative reconstructions showed significantly (p = 0.001 - p = 0.025) lower image noise and slightly higher image quality. Iterative reconstruction improved the accuracy of stenosis detection compared with FBP (per-patient: accuracy 96.9% vs. 93.8%, sensitivity 100% vs. 100%, specificity 94.6% vs. 89.2%, NPV 100% vs. 100%, PPV 93.3% vs. 87.5%). CONCLUSIONS: Iterative reconstruction significantly reduces image noise without loss of diagnostic information and holds the potential for substantial radiation dose reduction from cCTA.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Angiografia Coronária Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Angiografia Coronária Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Estados Unidos
...