Development of a sensitive HPLC method to measure in vitro permeability of E- and Z-isomeric forms of thiosemicarbazones in Caco-2 monolayers.
Debebe, Zufan; Nekhai, Sergei; Ashenafi, Meseret; Lovejoy, David B; Kalinowski, Danuta S; Gordeuk, Victor R; Byrnes, W Malcolm; Richardson, Des R; Karla, Pradeep K.
Afiliação
  • Debebe Z; Center for Sickle Cell Disease, Department of Medicine, Howard University College of Medicine, Washington, DC, United States.
Article em En | MEDLINE | ID: mdl-22954966
ABSTRACT
In the current study, we developed a HPLC method to quantitatively measure the permeability of the BpT-based chelators, 2-benzoylpyridine 4-ethyl-3-thiosemicarbazone (Bp4eT) and 2-benzoylpyridine 4-allyl-3-thiosemicarbazone (Bp4aT), across human colorectal adenocarcinoma (Caco-2) monolayers as a model of gut absorption. In aqueous solution, Bp4eT and Bp4aT formed inter-convertible Z and E isomers that were resolved by HPLC. Peak area was linear with respect to chelator concentration. Acceptable within-day and between-day precision (<22%) and accuracy (85-115% of true values) were obtained over a range of 1.0-100µM for Bp4eT and 1.5-300µM for Bp4aT. Limits of detection were 0.3µM and 1µM for Bp4eT and Bp4aT, respectively, while corresponding limits of quantification were 1µM and 5µM. Both chelators showed significant ability to chelate iron in THP-1 cells using a calcein-based assay and no apparent cytotoxicity was observed within 24h. Ratios of the apical to basolateral and basolateral to apical transport for Bp4eT were 1.10 and 0.89 at 100µM and 300µM respectively, indicating equal bi-directional movement of the compounds. Similarly, ratios were 0.77 and 0.92 for Bp4aT, respectively. This study demonstrates that Bp4eT and Bp4aT can be efficiently transported through Caco-2 cells and can potentially be formulated for oral delivery.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tiossemicarbazonas / Quelantes de Ferro / Cromatografia Líquida de Alta Pressão Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tiossemicarbazonas / Quelantes de Ferro / Cromatografia Líquida de Alta Pressão Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Estados Unidos
...