Bacteria killing nanotechnology Bio-Kil effectively reduces bacterial burden in intensive care units.
Hsueh, P-R; Huang, H-C; Young, T-G; Su, C-Y; Liu, C-S; Yen, M-Y.
Afiliação
  • Hsueh PR; Departments of Laboratory Medicine and Internal Medicine, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan.
Eur J Clin Microbiol Infect Dis ; 33(4): 591-7, 2014 Apr.
Article em En | MEDLINE | ID: mdl-24136062
A contaminated hospital environment has been identified as an important reservoir of pathogens causing healthcare-associated infections. This study is to evaluate the efficacy of bacteria killing nanotechnology Bio-Kil on reducing bacterial counts in an intensive care unit (ICU). Two single-bed rooms (S-19 and S-20) in the ICU were selected from 7 April to 27 May 2011. Ten sets of new textiles (pillow cases, bed sheets, duvet cover, and patient clothing) used by patients in the two single-bed rooms were provided by the sponsors. In the room S-20, the 10 sets of new textiles were washed with Bio-Kil; the room walls, ceiling, and air-conditioning filters were treated with Bio-Kil; and the surfaces of instruments (respirator, telephone, and computer) were covered with Bio-Kil-embedded silicon pads. Room S-19 served as the control. We compared the bacterial count on textiles and environment surfaces as well as air samples between the two rooms. A total of 1,364 samples from 22 different sites in each room were collected. The mean bacterial count on textiles and environmental surfaces in room S-20 was significantly lower than that in room S-19 (10.4 vs 49.6 colony-forming units [CFU]/100 cm(2); P < 0.001). Room S-20 had lower bacterial counts in air samples than room S-19 (33.4-37.6 vs 21.6-25.7 CFU/hour/plate; P < 0.001). The density of microbial isolations was significantly greater among patients admitted to room S-19 than those to room S-20 (9.15 vs 5.88 isolates per 100 patient-days, P < 0.05). Bio-Kil can significantly reduce bacterial burden in the environment of the ICU.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 2_ODS3 Problema de saúde: 2_enfermedades_transmissibles Assunto principal: Esterilização / Controle de Infecções / Nanotecnologia / Unidades de Terapia Intensiva Limite: Humans Idioma: En Revista: Eur J Clin Microbiol Infect Dis Assunto da revista: DOENCAS TRANSMISSIVEIS / MICROBIOLOGIA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 2_ODS3 Problema de saúde: 2_enfermedades_transmissibles Assunto principal: Esterilização / Controle de Infecções / Nanotecnologia / Unidades de Terapia Intensiva Limite: Humans Idioma: En Revista: Eur J Clin Microbiol Infect Dis Assunto da revista: DOENCAS TRANSMISSIVEIS / MICROBIOLOGIA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Taiwan
...