Your browser doesn't support javascript.
loading
Comparison of 3D multi-echo gradient-echo and 2D T2* MR sequences for the detection of arterial thrombus in patients with acute stroke.
Hodel, Jérôme; Leclerc, Xavier; Khaled, Wassef; Tamazyan, Ruben; Rodallec, Mathieu; Gerber, Sophie; Blanc, Raphael; Benadjaoud, Mohamed; Lambert, Oriane; Rabrait, Cécile; Zuber, Mathieu; Rahmouni, Alain; Zins, Marc.
Afiliação
  • Hodel J; Department of Radiology, Hôpital Saint Joseph, 186, rue Raymond Losserand, Paris, France, jerome.hodel@gmail.com.
Eur Radiol ; 24(3): 762-9, 2014 Mar.
Article em En | MEDLINE | ID: mdl-24254132
OBJECTIVES: We compared a multi-echo gradient-echo magnetic resonance sequence (susceptibility-weighted angiography [SWAN]) with the T2* sequence for the detection of an arterial thrombus in acute ischaemic stroke. METHODS: Seventy-four consecutive patients with acute ischaemic stroke were included. Proximal arterial occlusions were diagnosed using time-of-flight (TOF) magnetic resonance angiography (MRA). Two-dimensional (2D) axial reformats from 3D SWAN were generated to match with 2D T2* images. For arterial thrombus detection, each set of MR images (T2*, 2D SWAN reformats and 3D multiplanar SWAN images) was examined independently and separately by three observers who assigned the images to one of three categories: (0) absence of thrombus, (1) uncertain thrombus, (2) certain thrombus. Agreement and diagnostic accuracy were calculated. RESULTS: Twenty-four proximal arterial occlusions involving the anterior (n = 20) or posterior (n = 4) circulation were found. Inter-observer agreement was moderate using T2* images (κ = 0.58), good using 2D SWAN reformats (κ = 0.83) and excellent using multiplanar SWAN images (κ = 0.90). For the diagnosis of thrombus, T2* images were 54% sensitive and 86% specific, 2D SWAN reformats were 83% sensitive and 94% specific and SWAN multiplanar analysis was 96% sensitive and 100% specific. CONCLUSIONS: Three-dimensional SWAN sequence improves the detection of arterial thrombus in patients with acute ischaemic stroke in comparison with the 2D T2* sequence. KEY POINTS: • Multi-echo gradient-echo MR (e.g. susceptibility-weighted angiograph, [SWAN]) is increasingly used in neuroradiology. • Compared with conventional T2* sequences, SWAN improves detection of arterial thrombus. • Multiplanar SWAN analysis had the best diagnostic performance for arterial thrombus detection. • Sensitivity was 96% and specificity 100%. • Findings support combination of time-of-flight and susceptibility effects in suspected acute stroke.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Trombose / Imageamento por Ressonância Magnética / Isquemia Encefálica / Angiografia por Ressonância Magnética / Acidente Vascular Cerebral Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Trombose / Imageamento por Ressonância Magnética / Isquemia Encefálica / Angiografia por Ressonância Magnética / Acidente Vascular Cerebral Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2014 Tipo de documento: Article
...