Accuracy of GPS devices for measuring high-intensity running in field-based team sports.
Rampinini, E; Alberti, G; Fiorenza, M; Riggio, M; Sassi, R; Borges, T O; Coutts, A J.
Afiliação
  • Rampinini E; S. S. MAPEI srl, Human Performance Laboratory, Olgiate Olona, Italy.
  • Alberti G; Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milano, Italy.
  • Fiorenza M; Faculty of Exercise Sciences, Department of Sport, Università degli Studi di Milano, Nutrition and Health Sciences, Milan, Italy.
  • Riggio M; S. S. MAPEI srl, Human Performance Laboratory, Castellanza, Italy.
  • Sassi R; Training Check Juventus, Juventus Football Club, Turin, Italy.
  • Borges TO; School of Leisure, Sport & Tourism, University of Technology, Sydney, Australia.
  • Coutts AJ; School of Leisure, Sport & Tourism, University of Technology, Sydney, Lindfield, Australia.
Int J Sports Med ; 36(1): 49-53, 2015 Jan.
Article em En | MEDLINE | ID: mdl-25254901
ABSTRACT
We compared the accuracy of 2 GPS systems with different sampling rates for the determination of distances covered at high-speed and metabolic power derived from a combination of running speed and acceleration. 8 participants performed 56 bouts of shuttle intermittent running wearing 2 portable GPS devices (SPI-Pro, GPS-5 Hz and MinimaxX, GPS-10 Hz). The GPS systems were compared with a radar system as a criterion measure. The variables investigated were total distance (TD), high-speed distance (HSR>4.17 m·s(-1)), very high-speed distance (VHSR>5.56 m·s(-1)), mean power (Pmean), high metabolic power (HMP>20 W·kg(-1)) and very high metabolic power (VHMP>25 W·kg(-1)). GPS-5 Hz had low error for TD (2.8%) and Pmean (4.5%), while the errors for the other variables ranged from moderate to high (7.5-23.2%). GPS-10 Hz demonstrated a low error for TD (1.9%), HSR (4.7%), Pmean (2.4%) and HMP (4.5%), whereas the errors for VHSR (10.5%) and VHMP (6.2%) were moderate. In general, GPS accuracy increased with a higher sampling rate, but decreased with increasing speed of movement. Both systems could be used for calculating TD and Pmean, but they cannot be used interchangeably. Only GPS-10 Hz demonstrated a sufficient level of accuracy for quantifying distance covered at higher speeds or time spent at very high power.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Corrida / Futebol / Estudos de Tempo e Movimento / Sistemas de Informação Geográfica Limite: Adolescent / Humans / Male Idioma: En Revista: Int J Sports Med Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Corrida / Futebol / Estudos de Tempo e Movimento / Sistemas de Informação Geográfica Limite: Adolescent / Humans / Male Idioma: En Revista: Int J Sports Med Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Itália
...