Your browser doesn't support javascript.
loading
Bio-analytical method based on MALDI-MS analysis for the quantification of CIGB-300 anti-tumor peptide in human plasma.
Cabrales-Rico, Ania; de la Torre, Beatriz G; Garay, Hilda E; Machado, Yoan J; Gómez, Jose A; Audain, Enrique; Morales, Orlando; Besada, Vladimir; Marcelo, Jose Luis; Reyes, Vilcy; Perera, Yasser; Perea, Silvio E; Reyes, Osvaldo; González, Luis Javier.
Afiliação
  • Cabrales-Rico A; Chemical Synthesis Department, Center for Genetic Engineering and Biotechnology, Havana, Cuba.
  • de la Torre BG; Departament de Ciències Experimentals i de la Salut, UPF/PRBB, Barcelona, Spain.
  • Garay HE; Chemical Synthesis Department, Center for Genetic Engineering and Biotechnology, Havana, Cuba.
  • Machado YJ; Mass Spectrometry Department, Center for Molecular Immunology, Havana, Cuba.
  • Gómez JA; Mass Spectrometry Department, Center for Molecular Immunology, Havana, Cuba.
  • Audain E; Mass Spectrometry Department, Center for Molecular Immunology, Havana, Cuba.
  • Morales O; Mass Spectrometry Department, Center for Molecular Immunology, Havana, Cuba.
  • Besada V; Mass Spectrometry Laboratory, Proteomics Department, CIGB, Havana, Cuba.
  • Marcelo JL; Quality Assurance Unit, CIGB, Havana, Cuba.
  • Reyes V; Pharmaceutical Research Division, CIGB, Havana, Cuba.
  • Perera Y; Pharmaceutical Research Division, CIGB, Havana, Cuba.
  • Perea SE; Pharmaceutical Research Division, CIGB, Havana, Cuba.
  • Reyes O; Chemical Synthesis Department, Center for Genetic Engineering and Biotechnology, Havana, Cuba.
  • González LJ; Mass Spectrometry Laboratory, Proteomics Department, CIGB, Havana, Cuba. Electronic address: luis.javier@cigb.edu.cu.
J Pharm Biomed Anal ; 105: 107-114, 2015 Feb.
Article em En | MEDLINE | ID: mdl-25546027
A fully validated bio-analytical method based on Matrix-Assisted-Laser-Desorption/Ionization-Time of Flight Mass Spectrometry was developed for quantitation in human plasma of the anti-tumor peptide CIGB-300. An analog of this peptide acetylated at the N-terminal, was used as internal standard for absolute quantitation. Acid treatment allowed efficient precipitation of plasma proteins as well as high recovery (approximately 80%) of the intact peptide. No other chromatographic step was required for sample processing before MALDI-MS analysis. Spectra were acquired in linear positive ion mode to ensure maximum sensitivity. The lower limit of quantitation was established at 0.5 µg/mL, which is equivalent to 160 fmol peptide. The calibration curve was linear from 0.5 to 7.5 µg/mL, with R(2)>0.98, and permitted quantitation of highly concentrated samples evaluated by dilution integrity testing. All parameters assessed for five validation batches met the FDA guidelines for industry. The method was successfully applied to analysis of clinical samples obtained in a phase I clinical trial following intravenous administration of CIGB-300 at a dose of 1.6 mg/kg body weight. With the exception of Cmax and AUC, pharmacokinetic parameters were similar for ELISA and MALDI-MS methods.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos Cíclicos / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Antineoplásicos Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Cuba

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos Cíclicos / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Antineoplásicos Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Cuba
...