Influence of the physical data to calibrate TEPCs.
Chiriotti, S; Moro, D; Conte, V; Colautti, P; Grosswendt, B; Sterpin, E; Vynckier, S.
Afiliação
  • Chiriotti S; Belgian Nuclear Research Centre, SCK•CEN, Mol, Belgium Center of Molecular Imaging, Radiotherapy and Oncology, Institut de Recherche Expérimentale et Clinique, Université catholique de Louvain (UCL), Brussels, Belgium Laboratori Nazionali di Legnaro, INFN-LNL, Legnaro, Italy scalvare@sckcen.be.
  • Moro D; Laboratori Nazionali di Legnaro, INFN-LNL, Legnaro, Italy.
  • Conte V; Laboratori Nazionali di Legnaro, INFN-LNL, Legnaro, Italy.
  • Colautti P; Laboratori Nazionali di Legnaro, INFN-LNL, Legnaro, Italy.
  • Grosswendt B; Guest at LNL-INFN, Legnaro, Italy.
  • Sterpin E; Center of Molecular Imaging, Radiotherapy and Oncology, Institut de Recherche Expérimentale et Clinique, Université catholique de Louvain (UCL), Brussels, Belgium.
  • Vynckier S; Center of Molecular Imaging, Radiotherapy and Oncology, Institut de Recherche Expérimentale et Clinique, Université catholique de Louvain (UCL), Brussels, Belgium Cliniques universitaires Saint-Luc, Université catholique de Louvain, Brussels, Belgium.
Radiat Prot Dosimetry ; 166(1-4): 238-41, 2015 Sep.
Article em En | MEDLINE | ID: mdl-25877542
ABSTRACT
Tissue-equivalent proportional counters (TEPCs) measure distributions of ionisations, produced in the gas cavity by the radiation field which are afterwards converted into distributions of energy imparted by applying a calibration factor. To calibrate the pulse-height spectra, first, a marker point must be identified in the measured spectrum. Then, an accurate value of lineal energy must be assigned to this marker. A common marker that is often used for calibration is the so-called proton-edge (p-edge). It is a distinctive feature of a proton or neutron spectrum which corresponds to the maximum amount of energy that a proton can deposit in the active volume of the detector. A precise method to identify the marker point was applied to identify the p-edge with an uncertainty below 1 %. To evaluate the final uncertainty of the calibration, the uncertainty of the energy value assigned to the p-edge must also be considered. This value can be evaluated using different energy-range tables. This study investigates how the choice of different input databases for calibration purposes influences the calibration. The effect of three different frequently used sets of input data was analysed for pure propane gas and for propane-TE gas mixture.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Propano / Prótons / Radiometria / Transferência Linear de Energia / Raios gama / Nêutrons Tipo de estudo: Prognostic_studies Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Propano / Prótons / Radiometria / Transferência Linear de Energia / Raios gama / Nêutrons Tipo de estudo: Prognostic_studies Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Itália
...