Your browser doesn't support javascript.
loading
Spectrometer for shot-to-shot photon energy characterization in the multi-bunch mode of the free electron laser at Hamburg.
Palutke, S; Gerken, N C; Mertens, K; Klumpp, S; Mozzanica, A; Schmitt, B; Wunderer, C; Graafsma, H; Meiwes-Broer, K-H; Wurth, W; Martins, M.
Afiliação
  • Palutke S; Institute for Experimental Physics, University of Hamburg, Luruper Chaussee 149, D-22761 Hamburg, Germany.
  • Gerken NC; Institute for Experimental Physics, University of Hamburg, Luruper Chaussee 149, D-22761 Hamburg, Germany.
  • Mertens K; Institute for Experimental Physics, University of Hamburg, Luruper Chaussee 149, D-22761 Hamburg, Germany.
  • Klumpp S; Institute for Experimental Physics, University of Hamburg, Luruper Chaussee 149, D-22761 Hamburg, Germany.
  • Mozzanica A; Paul Scherrer Institute (PSI), Ch-5232 Villigen, Switzerland.
  • Schmitt B; Paul Scherrer Institute (PSI), Ch-5232 Villigen, Switzerland.
  • Wunderer C; Deutsches Elekronen Synchrotron (DESY), Notkestraße 85, D-22607 Hamburg, Germany.
  • Graafsma H; Deutsches Elekronen Synchrotron (DESY), Notkestraße 85, D-22607 Hamburg, Germany.
  • Meiwes-Broer KH; Institute for Physics, University of Rostock, Universitätsplatz 3, D-18051 Rostock, Germany.
  • Wurth W; Institute for Experimental Physics, University of Hamburg, Luruper Chaussee 149, D-22761 Hamburg, Germany.
  • Martins M; Institute for Experimental Physics, University of Hamburg, Luruper Chaussee 149, D-22761 Hamburg, Germany.
Rev Sci Instrum ; 86(11): 113107, 2015 Nov.
Article em En | MEDLINE | ID: mdl-26628121
ABSTRACT
The setup and first results from commissioning of a fast online photon energy spectrometer for the vacuum ultraviolet free electron laser at Hamburg (FLASH) at DESY are presented. With the use of the latest advances in detector development, the presented spectrometer reaches readout frequencies up to 1 MHz. In this paper, we demonstrate the ability to record online photon energy spectra on a shot-to-shot base in the multi-bunch mode of FLASH. Clearly resolved shifts in the mean wavelength over the pulse train as well as shot-to-shot wavelength fluctuations arising from the statistical nature of the photon generating self-amplified spontaneous emission process have been observed. In addition to an online tool for beam calibration and photon diagnostics, the spectrometer enables the determination and selection of spectral data taken with a transparent experiment up front over the photon energy of every shot. This leads to higher spectral resolutions without the loss of efficiency or photon flux by using single-bunch mode or monochromators.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Alemanha
...