Your browser doesn't support javascript.
loading
Dissolvable microneedle fabrication using piezoelectric dispensing technology.
Allen, Evin A; O'Mahony, Conor; Cronin, Michael; O'Mahony, Thomas; Moore, Anne C; Crean, Abina M.
Afiliação
  • Allen EA; School of Pharmacy, University College Cork, Cork, Ireland.
  • O'Mahony C; Tyndall National Institute, Lee Maltings, University College Cork, Cork, Ireland.
  • Cronin M; School of Pharmacy, University College Cork, Cork, Ireland.
  • O'Mahony T; School of Pharmacy, University College Cork, Cork, Ireland.
  • Moore AC; School of Pharmacy, University College Cork, Cork, Ireland; Dept. of Pharmacology, University College Cork, Cork, Ireland.
  • Crean AM; School of Pharmacy, University College Cork, Cork, Ireland. Electronic address: a.crean@ucc.ie.
Int J Pharm ; 500(1-2): 1-10, 2016 Mar 16.
Article em En | MEDLINE | ID: mdl-26721722
Dissolvable microneedle (DMN) patches are novel dosage forms for the percutaneous delivery of vaccines. DMN are routinely fabricated by dispensing liquid formulations into microneedle-shaped moulds. The liquid formulation within the mould is then dried to create dissolvable vaccine-loaded microneedles. The precision of the dispensing process is critical to the control of formulation volume loaded into each dissolvable microneedle structure. The dispensing process employed must maintain vaccine integrity. Wetting of mould surfaces by the dispensed formulation is also an important consideration for the fabrication of sharp-tipped DMN. Sharp-tipped DMN are essential for ease of percutaneous administration. In this paper, we demonstrate the ability of a piezoelectric dispensing system to dispense picolitre formulation volumes into PDMS moulds enabling the fabrication of bilayer DMN. The influence of formulation components (trehalose and polyvinyl alcohol (PVA) content) and piezoelectric actuation parameters (voltage, frequency and back pressure) on drop formation is described. The biological integrity of a seasonal influenza vaccine following dispensing was investigated and maintained voltage settings of 30 V but undermined at higher settings, 50 and 80 V. The results demonstrate the capability of piezoelectric dispensing technology to precisely fabricate bilayer DMN. They also highlight the importance of identifying formulation and actuation parameters to ensure controlled droplet formulation and vaccine stabilisation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Agulhas Idioma: En Revista: Int J Pharm Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Irlanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Agulhas Idioma: En Revista: Int J Pharm Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Irlanda
...