Your browser doesn't support javascript.
loading
Synergistic effect of up-flow constructed wetland and microbial fuel cell for simultaneous wastewater treatment and energy recovery.
Oon, Yoong-Ling; Ong, Soon-An; Ho, Li-Ngee; Wong, Yee-Shian; Dahalan, Farrah Aini; Oon, Yoong-Sin; Lehl, Harvinder Kaur; Thung, Wei-Eng.
Afiliação
  • Oon YL; School of Environmental Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia.
  • Ong SA; School of Environmental Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia. Electronic address: ongsoonan@yahoo.com.
  • Ho LN; School of Materials Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia.
  • Wong YS; School of Environmental Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia.
  • Dahalan FA; School of Environmental Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia.
  • Oon YS; School of Environmental Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia.
  • Lehl HK; School of Environmental Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia.
  • Thung WE; School of Environmental Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia.
Bioresour Technol ; 203: 190-7, 2016 Mar.
Article em En | MEDLINE | ID: mdl-26724550
ABSTRACT
This study demonstrated a successful operation of up-flow constructed wetland-microbial fuel cell (UFCW-MFC) in wastewater treatment and energy recovery. The goals of this study were to investigate the effect of circuit connection, organic loading rates, and electrode spacing on the performance of wastewater treatment and bioelectricity generation. The average influent of COD, NO3(-) and NH4(+) were 624 mg/L, 142 mg/L, 40 mg/L, respectively and their removal efficiencies (1 day HRT) were 99%, 46%, and 96%, respectively. NO3(-) removal was relatively higher in the closed circuit system due to lower dissolved oxygen in the system. Despite larger electrode spacing, the voltage outputs from Anode 2 (A2) (30 cm) and Anode 3 (A3) (45 cm) were higher than from Anode 1 (A1) (15 cm) as a result of insufficient fuel supply to A1. The maximum power density and Coulombic efficiency were obtained at A2, which were 93 mW/m(3) and 1.42%, respectively.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 2_ODS3 Problema de saúde: 2_quimicos_contaminacion Assunto principal: Fontes de Energia Bioelétrica / Purificação da Água / Conservação de Recursos Energéticos / Áreas Alagadas Idioma: En Revista: Bioresour Technol Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Malásia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 2_ODS3 Problema de saúde: 2_quimicos_contaminacion Assunto principal: Fontes de Energia Bioelétrica / Purificação da Água / Conservação de Recursos Energéticos / Áreas Alagadas Idioma: En Revista: Bioresour Technol Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Malásia
...