Your browser doesn't support javascript.
loading
Fatigue limit of polycrystalline zirconium oxide ceramics: Effect of grinding and low-temperature aging.
Pereira, G K R; Silvestri, T; Amaral, M; Rippe, M P; Kleverlaan, C J; Valandro, L F.
Afiliação
  • Pereira GKR; PhD Graduate Program in Oral Science, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil; Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands. Electronic address:
  • Silvestri T; Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil. Electronic address: taissilvestri@yahoo.com.
  • Amaral M; Graduate Program in Dentistry, University of Taubaté, Taubaté, Brazil. Electronic address: marinamaral_85@yahoo.com.br.
  • Rippe MP; PhD Graduate Program in Oral Science, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.
  • Kleverlaan CJ; Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands. Electronic address: c.kleverlaan@acta.nl.
  • Valandro LF; PhD Graduate Program in Oral Science, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil. Electronic address: lfvalandro@hotmail.com.
J Mech Behav Biomed Mater ; 61: 45-54, 2016 08.
Article em En | MEDLINE | ID: mdl-26828768
ABSTRACT
The following study aimed to evaluate the effect of grinding and low-temperature aging on the fatigue limit of Y-TZP ceramics for frameworks and monolithic restorations. Disc specimens from each ceramic material, Lava Frame (3M ESPE) and Zirlux FC (Ivoclar Vivadent) were manufactured according to ISO6872-2008 and assigned in accordance with two factors (1) "surface treatment"-without treatment (as-sintered, Ctrl), grinding with coarse diamond bur (181µm; Grinding); and (2) "low-temperature aging (LTD)" - presence and absence. Grinding was performed using a contra-angle handpiece under constant water-cooling. LTD was simulated in an autoclave at 134°C under 2-bar pressure for 20h. Mean flexural fatigue limits (20,000 cycles) were determined under sinusoidal loading using stair case approach. For Lava ceramic, it was observed a statistical increase after grinding procedure and different behavior after LTD stimuli (Ctrltemperature aging promoted a statistical increase in the fatigue limit (Ctrlfatigue test did not promote increase of m-phase content. Thus, tested grinding and low temperature aging did not damage the fatigue limit values significantly for both materials evaluated, even though those conditions promoted increase in m-phase.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ítrio / Zircônio / Teste de Materiais / Cerâmica Idioma: En Revista: J Mech Behav Biomed Mater Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ítrio / Zircônio / Teste de Materiais / Cerâmica Idioma: En Revista: J Mech Behav Biomed Mater Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2016 Tipo de documento: Article
...