Successful treatment of recurrent carotid in-stent restenosis and drug-eluting balloon failure with a coronary bioresorbable vascular scaffold: A case report.
Giordano, Arturo; Ferraro, Paolo; Corcione, Nicola; Messina, Stefano; Maresca, Gennaro; Coscioni, Enrico; Biondi-Zoccai, Giuseppe.
Afiliação
  • Giordano A; Unità Operativa di Interventistica Cardiovascolare, Presidio Ospedaliero Pineta Grande, Castel Volturno, Italy; Unità Operativa di Emodinamica, Casa di Salute Santa Lucia, San Giuseppe Vesuviano, Italy.
  • Ferraro P; Unità Operativa di Interventistica Cardiovascolare, Presidio Ospedaliero Pineta Grande, Castel Volturno, Italy; Unità Operativa di Emodinamica, Casa di Salute Santa Lucia, San Giuseppe Vesuviano, Italy.
  • Corcione N; Unità Operativa di Interventistica Cardiovascolare, Presidio Ospedaliero Pineta Grande, Castel Volturno, Italy; Unità Operativa di Emodinamica, Casa di Salute Santa Lucia, San Giuseppe Vesuviano, Italy.
  • Messina S; Unità Operativa di Interventistica Cardiovascolare, Presidio Ospedaliero Pineta Grande, Castel Volturno, Italy; Unità Operativa di Emodinamica, Casa di Salute Santa Lucia, San Giuseppe Vesuviano, Italy.
  • Maresca G; Unità Operativa di Interventistica Cardiovascolare, Presidio Ospedaliero Pineta Grande, Castel Volturno, Italy; Unità Operativa di Emodinamica, Casa di Salute Santa Lucia, San Giuseppe Vesuviano, Italy.
  • Coscioni E; Division of Cardiac Surgery, San Giovanni di Dio e Ruggì D'Aragona Hospital, Salerno, Italy.
  • Biondi-Zoccai G; Department of Medico-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Latina, Italy; Department of AngioCardioNeurology, IRCCS Neuromed, Pozzilli, Italy. Electronic address: giuseppe.biondizoccai@uniroma1.it.
Int J Surg Case Rep ; 21: 78-82, 2016.
Article em En | MEDLINE | ID: mdl-26945488
ABSTRACT

INTRODUCTION:

Carotid in-stent restenosis is associated with substantial risk of recurrent restenosis, even after drug-eluting balloon usage. PRESENTATION OF CASE We hereby report the case of a patient with recurrent carotid in-stent restenosis and drug-eluting balloon failure treated with a coronary bioresorbable vascular scaffold, achieving a satisfactory acute and long-term result, as disclosed by duplex ultrasound scan performed more than 1 year after the procedure. DISCUSSION/

CONCLUSION:

While awaiting for external validation, this clinical vignette supports expanding the armamentarium of endovascular specialists focusing on carotid artery disease, while providing further proof of the safety and efficacy of current bioresorbable vascular scaffolds.