Reliability of levator scapulae index in subjects with and without scapular downward rotation syndrome.
Lee, Ji-Hyun; Cynn, Heon-Seock; Choi, Woo-Jeong; Jeong, Hyo-Jung; Yoon, Tae-Lim.
Afiliação
  • Lee JH; Applied Kinesiology and Ergonomic Technology Laboratory, Department of Physical Therapy, The Graduate School, Yonsei University, Baekwoon-kwan, 1 Yonseidae-gil, Wonju, Kangwon-do, South Korea.
  • Cynn HS; Applied Kinesiology and Ergonomic Technology Laboratory, Department of Physical Therapy, The Graduate School, Yonsei University, Baekwoon-kwan, 1 Yonseidae-gil, Wonju, Kangwon-do, South Korea. Electronic address: cynn@yonsei.ac.kr.
  • Choi WJ; Applied Kinesiology and Ergonomic Technology Laboratory, Department of Physical Therapy, The Graduate School, Yonsei University, Baekwoon-kwan, 1 Yonseidae-gil, Wonju, Kangwon-do, South Korea.
  • Jeong HJ; Applied Kinesiology and Ergonomic Technology Laboratory, Department of Physical Therapy, The Graduate School, Yonsei University, Baekwoon-kwan, 1 Yonseidae-gil, Wonju, Kangwon-do, South Korea.
  • Yoon TL; Department of Physical Therapy, College of Health and Welfare, Woosong University, #17-2, Jayang-dong, Dong-gu, Daejeon, South Korea.
Phys Ther Sport ; 19: 1-6, 2016 May.
Article em En | MEDLINE | ID: mdl-27134210
ABSTRACT

OBJECTIVES:

The objective of this study was to introduce levator scapulae (LS) measurement using a caliper and the levator scapulae index (LSI) and to investigate intra- and interrater reliability of the LSI in subjects with and without scapular downward rotation syndrome (SDRS).

DESIGN:

Two raters measured LS length twice in 38 subjects (19 with SDRS and 19 without SDRS). MAIN OUTCOME

MEASURES:

For reliability testing, intraclass correlation coefficients (ICCs), standard error of measurement (SEM), and minimal detectable change (MDC) were calculated.

RESULTS:

Intrarater reliability analysis resulted with ICCs ranging from 0.94 to 0.98 in subjects with SDRS and 0.96 to 0.98 in subjects without SDRS. These results represented that intrarater reliability in both groups were excellent for measuring LS length with the LSI. Interrater reliability was good (ICC 0.82) in subjects with SDRS; however, interrater reliability was moderate (ICC 0.75) in subjects without SDRS. Additionally, SEM and MDC were 0.13% and 0.36% in subjects with SDRS and 0.35% and 0.97% in subjects without SDRS. In subjects with SDRS, low dispersion of the measurement errors and MDC were shown.

CONCLUSIONS:

This study suggested that the LSI is a reliable method to measure LS length and is more reliable for subjects with SDRS.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Escápula / Fenômenos Biomecânicos / Discinesias / Músculos Superficiais do Dorso Limite: Adult / Humans / Male Idioma: En Revista: Phys Ther Sport Assunto da revista: MEDICINA ESPORTIVA / MEDICINA FISICA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Coréia do Sul

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Escápula / Fenômenos Biomecânicos / Discinesias / Músculos Superficiais do Dorso Limite: Adult / Humans / Male Idioma: En Revista: Phys Ther Sport Assunto da revista: MEDICINA ESPORTIVA / MEDICINA FISICA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Coréia do Sul
...